PROGRAMMING - ENGLISH
x
Connect the emergency telephone to the alarm button (“ALARM”)
x
Connect the emergency telephone to an analogue telephone line
(“TELE”)
x
Set to programming mode. Programming can be initiated approximately
20 sec. after the telephone has been connected to the telephone line.
If breaking alarm button is used:
programming mode is activated by
pressing “0” and the alarm button for about 10 sec.
If closing alarm button is used:
Only “0” must be pressed after the
telephone line is connected. After programming of alarm button with closing
function, next activation of programming mode is done by pressing “0” and the
alarm button.
Programming mode is indicated by sound and flashing green LED. After each
programming sequence, a 4-tone beep confirms that the telephone has
accepted the programming. If no button is pushed during a time lapse of
30 sec., programming mode is automatically deactivated.
Jumper
Attach jumper should only be plugged in, next to green screw socket,
when all 3 conditions below prevail:
1. Single mounting of elevator telephone
2. Line voltage is lower than 32 VDC on telephone line
3. Elevator phone is connected to internal telephone exchange
(PABX)
N.B! Never connect to the public telephone net (PSTN) with jumper
attached!
R&TTE
Hereby Fält Communications AB declares that this product is in
compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC
0402
Here is a selection of the most common programming
functions. For a complete manual and programming guide, look at
www.faltcom.com
Connect the emergency telephone according to instructions above
Programming sequence
Description
Default
Reset to factory setting
X
Alarm button type
Alarm button with closing function
Alarm button with breaking function
X
Telephone number and alarm code
< 0123456789 >
Programming of first emergency call number
< 0123456789>
Programming of ID number 1. Must always be programmed!
< 0123456789>
Programming of second emergency call number
< 0123456789>
Programming of ID number 2. Must be programmed if the second number is
programmed!
Test of second number. Alarm is sent 1 min. after programming mode has been
deactivated. Test of first number is done by pressing the alarm button
Incomming calls
< 1 >
Activation of answering function
Deactivation of answering function
X
Alarm button delay
< 02-30 >
Delay time of an alarm button. Default setting is 5 seconds
05
Test alarm
< 3 >
Activation of test alarm function. Time in days
Deactivation of test alarm function
X
< 0123456789 >
Telephone number to test alarm receiver
< 0123456789 >
Alarm code for test alarm
Test of test alarm function. Sent 1 minute after programming mode has been deactivated
Acknowledgement of alarms
Disconnection of acknowledgement function
Reset to normal acknowledge sequence
X
Exit of programming mode
Deactivation of programming mode