When installing the cooker, disconnect the
equipment by removing the plug or switching off
the main switch.
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from mains power network before car-
rying out any operation on the cooker.
Make sure that electric wires inside the cooker are not disconnec-
ted or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law
in force.
Before connecting the cooker to the mains power network, check that:
• the mains voltage corresponds with the voltage indicated on the data plate
located inside the cooker;
• the electrical system is compliant and can withstand the load (see the tech
-
nical specifications located inside the cooker);
• the power supply plug and cable do not come into contact with temperat
-
ures exceeding 70 °C;
• the power supply system is effectively and properly connected to earth in
compliance with regulations in force.
• the socket used to connect the cooker is within reach.
In case of:
• devices fitted with cables without a plug: the type of plug to use is a ''stand
-
ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to
an adequate safety socket.
• fixed equipment not provided with a power supply cable and plug, or any
other device that ensures disconnection from the electrical mains, with an
opening gap of the contacts that enables total disconnection in overvoltage
category III conditions.
Said disconnection devices must be provided in the mains power supply in
compliance with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety
regulations.
Connection of the cooker (Panoramico 90):
network
Connection
Cable sec-
tion
Power ca-
ble
Switch
gauge
220V - 240V~
50/60Hz
1P+N / 2P
3 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
380V - 415V~
50/60Hz
2P+N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
380V - 415V~
50/60Hz
3P+N
5 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the contemporary factor in compliance with EN 60 335-2-6.
4
3
2
1
POWER:
Feature
90
90 Plus
Total power
2800-7400W
7400W
Position 1
Rated power
1600W
2100W
Booster power
1850W
3700W
Position 2
Rated power
2100W
2100W
Booster power (1/2)
3000W
3700W
Position 3
Rated power
2100W
2100W
Booster power (1/2)
3000W
3700W
Position 4
Rated power
1600W
2100W
Booster power
1850W
3700W