background image

15

2

1

1

2

Remove  the  flange  from  the  hood  (1),  detach the pre-cut elements and position the 

SLIM motor bracket (2).

SLIM MOTOR INSTALLATION

Содержание nube

Страница 1: ...INSTALLATION MANUAL falmecau com Nube...

Страница 2: ...REVIEW YOUR NEW ITEM TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES...

Страница 3: ...2 HOLE SIZES 540 973 925 492 370 556 128 min 10 max 25 341 239 275 95 275 150 940 505 NUBE 32 KG INSTALLATION WITH MOTOR ON THE HOOD...

Страница 4: ...3 HOLE SIZES 940 505 128 472 216 min 10 max 25 246 193 144 370 925 492 973 540 95 86 556 NUBE 31 KG INSTALLATION WITH SLIM MOTOR...

Страница 5: ...4 HOLE SIZES 940 505 540 973 925 492 370 556 128 min 10 max 25 275 275 86 216 193 95 144 NUBE 24 KG INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Страница 6: ...5 HOLE SIZES 940 505 973 492 925 128 540 min 10 max 25 95 150 130 NUBE 22 KG INSTALLATION WITH REMOTE MOTOR...

Страница 7: ...6 Max 1500 mm 9 mm MEASUREMENTS FOR INSTALLATION...

Страница 8: ...C O N T R O S O F F I T T O 2 m i n 6 0 m m min 60 mm 1 F A L S E C E I L I N G C O N T R O S O F F I T T O G 3 4 double adhesive 2 1 H H x 1 2 Cutting the plasterboard 1 inserting the supporting fram...

Страница 9: ...8 X Y X 1 2 Y 4 3 9 mm 3 Fixing the mandatory safety chains to the ceiling PRELIMINARY OPERATIONS...

Страница 10: ...9 1 4 2 3 2 1 4 5 PRELIMINARY OPERATIONS PRELIMINARY OPERATIONS Open the panel 4 and remove the filters 5...

Страница 11: ...10 INLET 1 2 3 Remove the flange from the hood 1 and the motor 2 If the air outlet is upward see 3 For other directions see 4 and 5 MOTOR ON HOOD INSTALLATION...

Страница 12: ...11 5 4 AIR 180 3 4 90 5 x 8 6 x 8 2 1 OUTLET Side movement of the air exhaust MOTOR ON HOOD INSTALLATION...

Страница 13: ...12 120 mm x8 x4 1 3 1 2 3 6 Fixing the motor support brackets 6 MOTOR ON HOOD INSTALLATION...

Страница 14: ...13 7 1 2 8 MOTOR ON HOOD INSTALLATION Fitting the non return valve 7 Positioning the motor on the support frame 8...

Страница 15: ...14 15 950 m3 h 1100 m3 h 150mm 1 2 3 9 Fitting the suction pipe and electrical connection 9 MOTOR ON HOOD INSTALLATION...

Страница 16: ...15 2 1 1 2 Remove the flange from the hood 1 detach the pre cut elements and position the SLIM motor bracket 2 SLIM MOTOR INSTALLATION...

Страница 17: ...16 A I R 145 5 S L I M L M 2 1 3 V 1 x8 4 V2 x4 3 Fixing the motor support brackets 3 SLIM MOTOR INSTALLATION...

Страница 18: ...17 1 2 L M H G SLIM 217mm 87mm 800 m3 h 1 2 3 4 5 Positioning the motor on the support frame 4 Fitting the suction pipe and electrical connection 5 SLIM MOTOR INSTALLATION...

Страница 19: ...18 120 mm AIR AIR 3 4 2 2 V2 x4 V1 x8 120 mm 3 V1 x8 4 V2 x4 2 1 Remove the flange from the hood 1 Fixing the brackets onto the rectangular connection 2 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Страница 20: ...19 1 2 L CT M H G 3 1 217mm 87mm CUE 2 4 Positioning the rectangular connection on the support frame 3 Fitting the suction pipe 4 INSTALLATION WITH CONVEYOR KIT AND REMOTE MOTOR...

Страница 21: ...20 1 2 150m m 200 mm KACL 396 N O V A L V E O P T I O N A L 1 2 Fitting the non return valve 1 INSTALLATION WITH REMOTE MOTOR...

Страница 22: ...21 F 1 2 REMOTE MOTOR REMOTE EXTERNAL MOTOR 3 Fixing the suction pipe 3 INSTALLATION WITH REMOTE MOTOR...

Страница 23: ...22 x2 2 1 CM 1 Final operations Passing the chains through passing the control cable through FINAL OPERATIONS...

Страница 24: ...23 Closing the holding brackets V 3 O K Disassembly 2 1 2 FINAL OPERATIONS...

Страница 25: ...24 C M C E 1 V4 2 V5 x 4 V6 x4 V5 x8 V5 x8 4 3 Fixing the motor or rectangular connection 3 electrical connection and tensioning the safety chains 4 FINAL OPERATIONS...

Страница 26: ...25 3 1 2 Repositioning filters and piston and closing the hood 5 FINAL OPERATIONS...

Страница 27: ...he safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or transferred to...

Страница 28: ...that are powered by energy other than electricity the negative pressure in the room must not exceed 4 Pa 4 x 10 5 bar HOOD WITH INTERNAL RECIRCULATION FILTERING In this model the air passes through an...

Страница 29: ...tions CLEANING OF INTERNAL SURFACES Do not clean electrical parts or parts related to the motor inside the hood with liquids or solvents For the internal metal parts see the previous paragraph METAL A...

Страница 30: ...ct by building materials of any kind will be required to be removed and reinstalled by the customer 10 PR Kitchens Washrooms has a service network in all metropolitan areas and most regional areas Whe...

Страница 31: ...30 NOTE NOTES...

Страница 32: ...o Treviso Italy falmec com Australia PR Kitchen Washroom Systems 83 Bangholme Rd Dandenong South VIC 3175 Australia 61 3 9700 9100 info prks com au New Zealand PR Kitchen Washroom Systems NZ P O Box 5...

Отзывы: