 SAFETY INSTRUCTIONS
 AND WARNINGS

Installation operations are to be carried 
out by skilled and qualified installers in ac-

cordance with the instructions in this booklet and 
in compliance with the regulations in force.
DO NOT use the hood if the power supply cable 
or other components are damaged: 

disconnect 

the hood from the electrical power supply and con-
tact the Dealer or an authorised Servicing Dealer for 
repairs. 

Do not modify the electrical, mechanical or func-
tional structure of the equipment.
Do not personally try to carry out repairs or re-
placements. Interventions carried out by incompe-
tent and unauthorised persons can cause serious 
damage to the unit or physical and personal harm, 
not covered by the Manufacturer's warranty.

WARNINGS FOR THE INSTALLER

TECHNICAL SAFETY

Before installing the hood, check the integ-
rity and function of each part. Should 

anomalies be noted, do not proceed with installa-
tion and contact the Dealer.

Do NOT install the hood if an aesthetic (or cos-
metic) defect has been detected. Put it back into 
its original package and contact the dealer.
No claim can be made for aesthetic (or cosmetic) 
defects once it has been installed.

During installation, always use personal protective 
equipment (e.g.: Safety shoes) and adopt prudent 
and proper conduct.
The installation kit (screws and plugs) supplied with 
the hood is only to be used on masonry walls: in case 
of installation on walls of a different material, assess 
other installation options keeping in mind the type 
of wall surface and the weight of the hood (indicated 
on page 2).
Keep in mind that installations with different types of 
fastening systems from those supplied, or which are 
not compliant, can cause electrical and mechanical 
seal danger.
Do not install the hood outdoors and do not expose 
it to atmospheric elements (rain, wind, etc.).

ELECTRICAL SAFETY

The electrical system to which the hood is to 

be connected must be in accordance with 

local standards and supplied with earthed connec-
tion in compliance with safety regulations in the 
country of use. It must also comply with European 
standards regarding radio antistatic properties. 

Before installing the hood, check that the electrical 

mains power supply corresponds with what is report-
ed on the identification plate located inside the hood.
The socket used to connect the installed equipment 
to the electrical power supply must be within reach: 
otherwise, install a mains switch to disconnect the 
hood when required. Any changes to the electrical 
system must be carried out by a qualified electrician. 
The maximum length of the flue fastening screws 
(supplied by the manufacturer) must be ½ in (13 mm). 
Use of non-compliant screws with these instructions 
can lead to danger of an electrical nature.
Do not try to solve the problem yourself in the event 
of equipment malfunction, but contact the Dealer or 
an authorised Servicing Department for repairs.

When installing the hood, disconnect the 

equipment by removing the plug or switch-

ing off the main switch.

FUMES DISCHARGE SAFETY

Do no connect the equipment to discharge 
pipes of fumes produced from combustion 

(for example boilers, fireplaces, etc.).

Before installing the hood, ensure that all standards in 
force regarding discharge of air out of the room have 
been complied with.

USER WARNINGS

These warnings have been drawn up for 

your personal safety and those of others. 

You are therefore kindly asked to read the book-
let carefully in its entirety before using the or 
cleaning the equipment.
The Manufacturer declines all responsibility for 
any damage caused directly, or indirectly, to per-
sons, things and pets as a consequence of failing 
to comply with the safety warnings indicated in 
this booklet.
It is imperative that this instructions booklet is 
kept together with the equipment for any future 
consultation.

If the equipment is sold or transferred to another per-
son, make sure that the booklet is also supplied so 
that the new user can be made aware of the hood's 
operation and relative warnings. 
After the stainless steel hood has been installed, it 
will need to be cleaned to remove any residues re-
maining from the protection adhesive as well as any 
grease and oil stains which, if not removed, can cause 
irreversible damage to the hood surface. To properly 
clean the unit, the manufacturer recommends using 
the supplied moist wipes, which are also available 
sold separately. 

Insist on original spare parts.

Содержание Gruppo Incasso NRS FNINS28B5SS

Страница 1: ...EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI Gruppo incasso NRS FNINS20B5SS FNINS28B5SS...

Страница 2: ...tool required FR outil requis ES herramienta requerida IT Attrezzi necessari 29 9 16 751 mm 10 5 16 262 mm 5 15 16 150 mm 120 mm 4 3 4 11 9 16 293 mm 11 5 8 max 295 mm 12 3 8 max 315 mm 22 29 1 8 740...

Страница 3: ...tool required FR outil requis ES herramienta requerida IT Attrezzi necessari 14 7 8 506 mm 10 5 16 262 mm 5 15 16 150 mm 120 mm 4 3 4 11 9 16 293 mm 11 5 8 max 295 mm 12 3 8 max 315 mm 22 19 7 16 494...

Страница 4: ...desde la super cie de coc ci n hasta el fondo de la campana se indica con una A en el di bujo siguiente Se recomienda instalar la campana en este ran go para optimizar el rendimiento Se recomienda no...

Страница 5: ...EN Hood installation 4 fitting to the wall unit 5 FR Mise en place de la hotte 4 fixation au meuble 5 ES Introducci n campana 4 fijaci n en el armario de pared 5 IT Inserimento cappa 4 fissaggio al p...

Страница 6: ...8 FR Installation clapet de non retour 6 chambre moteur 7 et branchement lectrique 8 ES Instalaci n de la v lvula de no retorno 6 compartimento del motor 7 y cone xi n el ctrica 8 IT Installazione val...

Страница 7: ...9 and electrical connection 10 FR Repositionner le filtre m tallique 9 et branchement lectrique 10 ES Volver a colocar el filtro met lico 9 y conexi n el ctrica 10 IT Rimettere i filtri metallici 9 e...

Страница 8: ...C B V3 x 3 1 2 3 11 12 H X 4 11 16 H X 120 mm 35 mm B A NRS NRS V3 x3 x3 1 2 3 A min 7 1 2 min 190 mm F EN Fastening of NRS pipe FR Fixation du tube NRS ES Fijaci n del tubo NRS IT Installazione tubo...

Страница 9: ...9 EN Flue assembly FR Montage de la cheminee ES Montaje de la chimenea IT Assemblaggio camino 3 V2 V6 2 4 5 6 4 mm V4 V5 V5 V6 V4 G 1 H 1 13...

Страница 10: ...8 250 mm EN Installing the carbon zeolite filter optional FR Installation du iltre charbon zeolite en option ES Instalacion de iltro de carbon zeolita opcional IT Installazione filtro carbone zeolite...

Страница 11: ...rding radio antistatic properties Before installing the hood check that the electrical mains power supply corresponds with what is report ed on the identi cation plate located inside the hood The sock...

Страница 12: ...s INSTALLATION only intended for qualified personnel Before installing the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical speci cations are exhibited...

Страница 13: ...trong odours and vapours 4th speed rapid disposal of odours and vapours WHEN SHOULD THE FILTERS BE WASHED OR REPLACED The metal lters must be cleaned every 30 hours of operation For further details se...

Страница 14: ...a month leaving them to soak in boiling water and cleaning solution for 1 hour taking care not to bend them Do not use corrosive acid or alkaline detergents Rinse them well and wait for them to be com...

Страница 15: ...e aux normes et muni d un raccordement la terre conform ment aux normes de s curit du pays d utilisation il doit en outre tre conforme aux normes europ ennes sur l antiparasite radio Avant d installer...

Страница 16: ...la hotte sans les ltres m talliques anti graisse dans ce cas la graisse et la salet se d poseraient dans l appareil et compromettrait son fonctionnement Des parties accessibles de la hotte peuvent tre...

Страница 17: ...e raccord de sortie de d air du moteur INSTRUCTIONS DE MONTAGE partie r serv e uniquement un personnel qualifi ATTENTION V rifier que l acc s frontal au meuble soit libre La hotte peut tre install e s...

Страница 18: ...reil en enlevant la fiche ou en agissant sur l interrupteur g n ral Il ne faut pas utiliser de d tergents contenant des substances abrasives acides ou corrosives ni de chiffons ayant des surfaces r ch...

Страница 19: ...point d limination d sign le plus proche Des amendes pourraient tre appliqu es pour l limination incorrecte de ces d chets conform ment la l gislation nationale INFORMATIONS SUR L LIMINATION DANS LES...

Страница 20: ...rferen cias radio Antes de instalar la campana controle que la tensi n de red coincida con la indicada en la placa coloca da en el interior de la campana La toma usada para la conexi n el ctrica debe...

Страница 21: ...gares etc alimentados con gas o con otros combustibles prevea una adecuada ventilaci n del ambiente donde se realiza la aspiraci n de humos seg n las normas vigentes INSTALACI N parte reservada al per...

Страница 22: ...Y QUE ENCENDER LA CAMPANA Encienda la campana al menos un minuto antes de comenzar a cocinar para transportar los humos y vapores hacia la super cie de aspiraci n Cuando nalice la cocci n deje en func...

Страница 23: ...rruptor general No deben utilizarse detergentes que contengan sustancias abrasivas ci das o corrosivas ni pa os con superficies rugosas Un mantenimiento constante asegura un buen funcionamiento y un p...

Страница 24: ...i n nacional INFORMACI N ACERCA DE LA ELIMINACI N EN LOS PA SES DE LA UNI N EUROPEA La directiva comunitaria sobre los equipos RAEE ha sido acatada de forma diver sa en cada pa s por tanto si quiere e...

Страница 25: ...e la cappa veri care che la tensione di rete corrisponda a quella riportata dalla targhetta posta all interno della cappa La presa usata per il collegamento elettrico deve es sere facilmente raggiungi...

Страница 26: ...ore generale quando l apparec chio non viene utilizzato per periodi prolungati di tempo In caso di utilizzo contemporaneo di altre utenze caldaie stufe caminetti ecc ali mentate a gas o con altri comb...

Страница 27: ...riche valgono per tutte le instal lazioni seguire invece dove specificato le fasi corrispondenti all installazione desiderata FUNZIONAMENTO QUANDO ACCENDERE LA CAPPA Accendere la cappa almeno un minut...

Страница 28: ...ostanze abrasive acide o corrosive e panni con superfici ruvide Una costante manutenzione garantisce un buon funzionamento e rendimento nel tempo Particolari attenzioni vanno rivolte ai ltri metallici...

Страница 29: ...esti ri uti in conformit alla legislazione nazionale INFORMAZIONI SULLO SMALTIMENTO IN NAZIONI DELL UNIONE EURO PEA La Direttiva comunitaria sulle apparecchiature RAEE stata recepita in modo diverso d...

Страница 30: ...30 NOTE NOTES...

Страница 31: ...31 NOTE NOTES...

Страница 32: ...Code 110033096 Ed 00 2020 FALMEC S p A 31029 VITTORIO VENETO Treviso ITALY Zona Industriale Via dell Artigianato 42 www falmec com Codice Code Matricola Serial Number...

Отзывы: