5.6.4 Installation Orientation:

 All Removable Concrete Anchors discussed in this manual, when deployed as single person anchors may 

 

self-orient or bend up to 90 degrees towards the user’s work area and/or PFAS. Do not bend or pull the anchor beyond 90 degrees. See    

 

Figure 7.

 

5.6.3 Retractor Handle:

 The wedge chocks that bite into the concrete to secure the anchor may be positioned either vertically or 

 

horizontally. Best practice during installation of the anchor is to ensure the retractor handle is level with the surface. If the retractor 

 

handle is not level with the surface the cables will kink and the damage to the anchor will occur.  See Figure 6.

Figure 6 - Retractor Handle

90º

90º

GOOD

GOOD

BEST

Figure 6 - Loading Direction

 

5.6.1 Cracked Concrete Installation:

 The anchors described in this manual are designed for installation in un-cracked concrete conditions.   

 

Use of these anchors in cracked concrete conditions is not allowed. For concerns over the suitability of substrate in a cracked concrete 

 

environment, a qualified engineer shall be consulted.

 

5.6.2 Re-installing the Anchor in a Previously Used Hole:

 The anchors discussed in this manual may be re-inserted in a previously used    

 

anchor insertion hole that passes pre-use inspection. The previously used hole must still retain the same depth, diameter, and functional    

 

properties as described in the original installation requirements. Any anomalies such as cracking of the concrete, widening of the hole, 

 

or wearing of the hole from overuse will require the drilling of a new anchor insertion hole. If there is any doubt about the integrity of the   

 

anchor insertion hole, then a new hole must be drilled.

MANC36 Rev A

042921

7

Figure 5 - Installation Instructions

D

   

A

B

A

Using the proper hammer drill bit, drill a 3/4” diameter hole at least 3.5” deep into the concrete and at least 

the minimum edge distance for the given concrete dimensions described in Figure 4.  Hole must be straight and 

perpendicular to concrete surface.

B

Remove dust and debris from hole using hand pump, compressed air, or vacuum.  Hole must be completely free of 

dust and debris before installing anchor.

C

To place the anchor, place you thumb inside the ring and first two fingers around the trigger.  Squeeze your thumb and 

fingers together until the trigger and spring fully compress.  Insert unit at least 3” into the drilled hole and release the 

trigger.

D

Set the unit with a slight tug on the ring.  The stop sleeve should always be partially inserted into the hole.

C

Содержание 7443

Страница 1: ...CA 90221 USA Tel 800 719 4619 Fax 323 752 5613 This manual is intended to meet the Manufacturer s Instructions as required by the American National Standards Institute ANSI Z359 and should be used as...

Страница 2: ...Maintenance Service and Storage 7 0 Inspection 8 0 Labels 9 0 Specifications 3 4 4 5 6 8 8 10 10 MANC36 Rev A 042921 2 For purposes of this manual the FallTech Removable Concrete Anchor in all iterati...

Страница 3: ...eath due to falls because of increased fall arrest forces placed on the user s body In addition the onset of suspension trauma after a fall even may be accelerated for heavy users The user of the equi...

Страница 4: ...ecomes difficult to remove IN ALL CASES A COMPETENT PERSON SHALL INSPECT FOR PROPER INSTALLATION AND REMOVAL OF THE REMOVABLE CONCRETE ANCHOR 3 4 Approved Applications Below are applications for which...

Страница 5: ...n a way that would produce a condition of loading on the gate D Never attach to a object in a manner whereby the gate of the snap hook or carabiner would be prevented from fully closing and locking Al...

Страница 6: ...quipment must determine the MRFC for units discussed in this manual to ensure adequate clearance exists in the fall path Variables discussed in this manual include the height of the anchor point relat...

Страница 7: ...anual may be re inserted in a previously used anchor insertion hole that passes pre use inspection The previously used hole must still retain the same depth diameter and functional properties as descr...

Страница 8: ...or death 6 3 Storage Store in a clean dry and chemical free environment and kept out of direct sunlight 6 0 Maintenance Service and Storage 7 0 Inspection 7 1 Pre Use Inspection Please review the Pre...

Страница 9: ...rial _________________________ Date of Manufacture _________________________ INSPECTION DATE INSPECTOR COMMENTS PASS FAIL CORRECTIVE ACTION NEEDED APPROVED BY 7 4 Inspection Document Record inspection...

Страница 10: ...Concrete Anchor Model Application Dimensions Minimum Tensile Strength and Material Maximum User Capacity Image 7443 Expansion Wedge Anchor with Swaged Loop Cured Concrete 3 000 psi Min 11 3 4 Drilled...

Отзывы: