Training and competence  

To help ensure the safe use of this appliance there is a requirement for you to provide 
whatever information, instruction, training and supervision as is necessary to ensure, so 
far as is reasonably practicable, the health and safety of all users. 

For further help and information on training and competence we would refer you the 
Health and Safety Executive website; 

www.hse.gov.uk

 document ref: health and safety 

training INDG345. International customers should default to the health and safety 
guidelines provided by your government body. 
 

Risk assessment  

As part of managing the health and safety of your business you must control any risks 
identified in your commercial kitchen. To do this you need to think about what might 
cause harm to people and decide whether you are taking reasonable steps to prevent 
that harm. This is known as risk assessment. It is important to consider the environment 
around the product as well as the product itself. For example oil or food spills will present 
a significant risk so users so the need to immediately clean up such spills must be 
reflected in staff training. 

For further help and information on risk assessments we would refer you to you the 
Health and Safety Executive website; 

www.hse.gov.uk

 document ref: risk assessment 

INDG163. International customers should default to the health and safety guidelines 
provided by your government body. 

 

 

Содержание PH1

Страница 1: ...User Installation and servicing instructions MOBILE PLATE DISPENSER PH1 PH2 Read these instructions before use T101044 Rev No 5 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Страница 2: ...e of appliance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable...

Страница 3: ...SYMBOLS SCREWDRIVER SPANNER COOKING OIL GREASE WARNING SPARK IGNITION FLAME VIEWPORT ALLEN KEY IGNITER C SPANNER REMOVE DEVICE PLUG REMOVER...

Страница 4: ...ust instruct the responsible person s of the correct operation and maintenance of the appliance Unless otherwise stated parts which have been protected by the manufacturer must not be adjusted by the...

Страница 5: ...ealth and safety of your business you must control any risks identified in your commercial kitchen To do this you need to think about what might cause harm to people and decide whether you are taking...

Страница 6: ...MAINTENANCE 5 4 0 SPECIFICATION 6 4 1 APPLIANCE WEIGHT TABLE 6 4 2 TECHNICAL DATA TABLE 6 5 0 DIMENSIONS CONNECTION LOCATIONS 7 6 0 INSTALLATION 8 6 1 SITING CLEARANCES 9 6 2 ASSEMBLY 9 6 3 ELECTRIC S...

Страница 7: ...cal and Electromagnetic Compatibility EMC Regulations Directives for the voltages stated on the data plate A Serial No B Model No C Flue Type D Gas Category E Gas Pressure F Gas Type G Gas Rate H Tota...

Страница 8: ...2 2 0 OPERATION 2 1 COMPONENT PARTS 2 2 CONTROLS...

Страница 9: ...at position to determine the satisfactory level for the application Load the plate Lowerator with the required amount of crockery Place crockery in the dispenser small stacks at a time Be careful not...

Страница 10: ...ld water and hot oil for example are an explosive mix and should be avoided at all costs Other useful references for health and safety issues www hse gov uk Essentials of health and safety at work ISB...

Страница 11: ...y be caused If used inadvertently rinse immediately with clean water Do not splash the unit with bleach when cleaning around the counter If you do rinse the surface immediately with clean water thorou...

Страница 12: ...kg PACKED WEIGHT kg PH1 35Kg 42Kg PH2 50Kg 58Kg 4 2 TECHNICAL DATA TABLE CURRENT POWER MIN A 230V MAX A 230V ACTUAL A 230V kW 230V PH1 1 57 1 83 1 75 0 400 PH2 3 15 3 65 3 50 0 800 IF ANY CURRENT IS O...

Страница 13: ...7 5 0 DIMENSIONS CONNECTION LOCATIONS...

Страница 14: ...nnector must meet the specification requirements of IEC 60947 Your attention is drawn to BS 7671 2018 Guidance Note 8 8 13 Other locations of increased risk It is recognized that there may be location...

Страница 15: ...it is recommended that they be made of a non combustible material or clad in a suitable non combustible heat insulating material and that the closest attention be paid to fire preventative regulation...

Страница 16: ...are inspected daily Check for damage to the plug housing pins and the mains cable is secured to plug with no wires showing When checking the plug and cable the wall socket should also be inspected fo...

Страница 17: ...level with the top of the dispenser guides Note All installed springs are connected during assembly of the dispenser 5 With one or two plates placed centrally in the dispenser place the adjustable gu...

Страница 18: ...tified these should be replaced If the appliance is not considered safe the unit should be removed from service and the responsible person advised why the unit is not safe to use and what remedial act...

Страница 19: ...wo allen bolts and remove front cover 7 1 7 Remove front panel disconnect earth wires and lift the dispenser from the appliance 7 1 8 Replace any defective parts 7 1 9 Reassembly is the reverse of dis...

Страница 20: ...e policy Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Warranty calls can be made between 8 30 am and 5 00 pm weekdays only To ensure your war...