40
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Connection in New Zealand
Type of cord in accordance with
IEC 60227
with a minimum
rating of 90°C.
Cord size recommended for this application is 3 x 10 mm²,
three-core cable (Power cables may be sized to take into
account the coincidence factor
AS/NZS 60335.2.6:2014
).
Rating of the plug is 32 Amp, in accordance with
AS/NZS
3112
. Based on the arithmetic mean value when measured
under full load stabilized conditions,
Clause 10 IEC 60335-1
.
If this cooking range is to be connected to a new or upgrade
electrical installation, then it must be connected to the
supply by a supply cord fitted with:
•
An appropriately rated plug that is compatible with the
socket – outlet fitted to the final sub –circuit in the fixed
wiring that supplies this cooking range
OR
•
An appropriately rated installation male connector that
is compatible with the installation female connector
fitted to the final sub circuit in the fixed wiring that
supplies this cooking range.
Note:
The marking for the rated current of the fuse protecting
a socket should be placed on or near the socket outlet.
Fixed Wiring
n
DISCONNECT FROM THE MAINS SUPPLY.
For connection to fixed wiring, i.e. flexible conduit, remove
the electrical terminal cover on the back panel (
Fig. 8.13
).
Fit the conduit box to the cooker using the two M5 screw
fittings located at the top of the box. Remove the M4 screw
from the base, and fix to the cooker, via the fitting through
the back of the conduit box (
Fig. 8.14
).
The conduit box cover is reversible. Fit the reducer plate if
required (
Fig. 8.15
). Feed the cable through the conduit box
and secure in place with the cable clamp.
Connect the mains cable to the correct terminals for your
electrical supply type (
Fig. 8.16
). Check that the links are
correctly fitted and that the terminal screws are tight.
Fit the cover to the conduit box.
Conduit box
M4 screw
M5 screws
Reducer plates
Reversible conduit box cover
ArtNo.132-0002 - 3 phase 240/415Vac 50Hz
3-phase 400 V
AC
50 Hz
Fig. 8.13
Fig. 8.14
Fig. 8.15
Fig. 8.16