background image

Model

kW

Btu/hr

G350/11

11.8

40,250

G350/12

23.6

80,500

Gas Type

MAIN

BURNER

PILOT

BURNER

NATURAL

ù2.85mm SIT No.36

PROPANE

ù1.70mm SIT No.19

SECTION 1 - INSTALLATION

1.2 SITING
These appliances must be installed on a firm, level

floor in a well lit position.
The fryers can be positioned to within 75mm of a

compustible wall, but to allow space for the removal

of side panels, a clearance of about 150mm should

be provided at the back. There should be a minimum

vertical clearance of 900mm above the top edge of

appliance flue to any overhanging combustible sur-

face.
IMPORTANT If the appliance is tobe installed with

other matching appliances of the Falcon 350 series,

the Instructions for all units must be consulted to

determine the necessary clearance toany

combustible rear wall or overlying surface. Some

appliances require greater clearances than others,

and the largest figure quoted in the individual

Instructions will therefore determine the clearance

for the complete suite of adjoining appliances.

1.3 VENTILATION
The appliance flue discharges vertically through the

grille at the rear of the hob. There must be no direct

connection of the flue to any mechanical extraction

system or the outside air. Siting the appliance under a

ventilated canopy is the ideal arrangement.

Adequate ventilation, whether natural or mechanical,

must be provided to ensure sufficient fresh air for

combustion and for removal of combustion products,

which may be harmful to health. Recommendations

for ventilation for Catering Appliances are given in

BS.5440:2. Further, to ensure sufficient room venti-

lation, guidance on the volume of ventilation air

required for different kinds of catering equipment is

given in the table. For multiple installations the

requirements should be added. Installation should

be made in accordance with local and/ or national

regulations applying at the time, and a competent

installer must be employed.

1.4 GAS SUPPLY
The incoming service must be of sufficient size to

supply full rate without excessive pressure drop. A

gas meter is connected to the service pipe by the Gas

Supplier. Any existing meter should be checked,

preferably by the Gas Supplier, toensure that the

meter is of adequate capacity to supply the fryer, and

other associated equipment. This is particularly

important when a number of units are being installed.
Installation pipework should be fitted in accordance

with IGE/UP/2. The size of the pipes from the meter

to the appliance must be not less than that of the

appliance inlet connection, Rp

1

/

2

(

1

/

2

" BSP female).

An isolating cock must be located close to the

appliance tofacilitate shut-do

wn during an

emergency or routine servicing. The cock must be

easily accessible tothe user. The installation must be

tested for gas-soundness; details are given in

IGE/UP/1. The adjustable governor supplied must

be fitted tonatural gas appliances.

1.5 ELECTRICAL SUPPLY
Not applicable to these appliances.

1.6WATER SUPPLY
Not applicable to these appliances.

1.7 HEAT INPUTS -

NATURAL and PROPANE GAS

The G350/12 incorporates two burner systems

identical tothat within the G350/11.

1.8 INJECTOR SIZES -

NATURAL and PROPANE GAS

EQUIPMENT

Ventilation Rate Required

m

3

/ min

ft

3

/min

Range, Unit Type

17

600

Pastry Oven

17

600

Fryer

26

900

Grill

17

600

Steak Grill

26

900

Boiling Pan

17

600

Steamer

17

600

Sterilizing Sink

14

500

Bains Marie

11

400

Tea/ Coffee Machine

8.5 - 14

300 - 500

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER

ARE NOT TO BE ADJUSTED BY THE INSTALLER

MODEL

WIDTH

mm

DEPTH

mm

HEIGHT

mm

WEIGHT

kg

WEIGHT

lbs

G350/11

350

650

870

46

102

G350/12

700

650

870

84

185

1.1 MODEL NUMBERS, NETT WEIGHTS

and DIMENSIONS

All manuals and user guides at all-guides.com

Содержание G350/12

Страница 1: ...ing Further to this the users instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance Particular emphasis should be made with regard to...

Страница 2: ...l supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a...

Страница 3: ...uld be added Installation should be made in accordance with local and or national regulations applying at the time and a competent installer must be employed 1 4 GAS SUPPLY The incoming service must b...

Страница 4: ...ll of pan Purge air from system and light burner using the following procedure Warning If pilot is extinguished either intentionally or unintentionally wait at least 3 minutes before re lighting gas a...

Страница 5: ...From underneath the burner remove fixings that secure pilot bracket to burner Ease pilot burner assembly clear of burner by moving it slightly downward c Remove four screws securing burner support st...

Страница 6: ...o operate it will be necessary to remove sensor bulb of control thermostat from oil This condition can be accomplished by the following procedure a Drain pan b Remove upper panel above door by removin...

Страница 7: ...e interruptor h Undo four fixings and remove control chamber base panel j Undo small gland nut sealing capillary tube where it enters fryer pan See Figure 2 k Remove phial guard and ease phial through...

Отзывы: