mbar
inches w.g.
6
14.8
15
37
NATURAL
PROPANE
1.9 GAS PRESSURE
NATURAL and PROPANE GAS
1.10 BURNER ADJUSTMENTS
Noadjustments are provided, since burners have
fixed injectors and aeration.
SECTION 2 - ASSEMBLY and
COMMISSIONING
2.1 ASSEMBLY
1. Check parts supplied Check that each pan is
equipped with twochip baskets, pan base panel
and dust cover. (These parts may be packed
separately). On NATURAL gas models, an
adjustable governor is also supplied.
2. Place unit in position, and level using feet
adjusters. For safety reasons, both units must be
fixed to floor. Holes are provided in feet for this
purpose.
2.2 CONNECTION TO THE GAS SUPPLY
Installation should be carried out in accordance with
various regulations listed on the cover of this manual.
On NATURAL gas appliances, the adjustable
governor supplied must be fitted in supply. Securely
fixed in a position enabling adjustment to be made
during commissioning. On propane appliances, do
not fit a governor.
2.3 CONNECTION TO AN ELECTRICITY SUPPLY
Not applicable to these appliances.
2.3 CONNECTION TO A WATER SUPPLY
Not applicable to these appliances.
2.5 PRE-COMMISSIONING CHECK
After connecting gas supply, fit a pressure gauge to
pressure test point, and check installation for gas
soundness.
To remove protective surface film from pan, clean
pan thoroughly using hot water and detergent.
Rinse out and dry.
Ensure drain valve is closed and fill pan with oil to
level indicated on rear wall of pan.
Purge air from system and light burner using the
following procedure:
Warning
If pilot is extinguished either intentionally or
unintentionally, wait at least 3 minutes before
re-lighting gas.
a) Ensure that pan contains oil up to level mark
embossed on rear wall of the pan.
b) Open cabinet door, gaining access to controls.
c) Refer to Figure 2 and turn thermostat knob
clockwise to pilot position .
d) Press rectangular button marked
and hold in.
e) Press spark igniter button and observe that pilot
lights. If it does not light immediately, repeatedly
press and release ignition button until it does.
f) Hold ignition button in for a further 20 seconds and
release button. Observe that pilot remains lit.
If it should go out, wait three minutes then repeat
from (d).
g) Having established pilot, turn control knob anti-
clockwise to maximum setting and main burner
will light.
h) On NATURAL gas units, if necessary, adjust
governor to produce required pressure of 15mbar
(6 inches w.g.) on gauge previously fitted.
To affect this, remove governor cap to access
screw and turn it clockwise to increase pressure
and vice-versa. Replace governor cap after
correct pressure has been established.
Allow pan to heat up and check that thermostat
shuts off gas to main burner when maximum
temperature is reached.
j) When satisfied that fryer is functioning properly,
shut off gas by pressing OFF button (Figure 1).
k) Remove pressure gauge and replace pressure
test-point screw.
Note
The main burner can be shut off while leaving pilot lit
by turning control knob clockwise to the
position.
Figure 1 - Gas Control Valve
All manuals and user guides at all-guides.com