background image

Natural

Propane

mbar

15.5

37

inches w.g

6.2

14.8

mbar

20

14.8

inches w.g

8

14.8

Burner Pressure

Supply Pressure

1.9 GAS PRESSURE
The pressure test point is situated on gas manifold

behind front facia panel.

1.10 BURNER ADJUSTMENTS
1.10.1 Aeration Adjustment
The burners are fitted with fixed injectors.
Aeration is set and sealed by manufacturer by means

of a screw in burner throat. After setting the pressure,

flame quality should be such that there is no evidence

of flame lift or light back. Also refer to Servicing

Instructions, Section 3.3.
1.10.2 Low Flame Setting
Low flame adjustment has been set and sealed by

manufacturer by means of a bypass screw in gas tap

to approximately half full rate.

SECTION 2 - ASSEMBLY and

COMMISSIONING

2.1 ASSEMBLY
1. The burners, bottomgrates and cooking bars are

removed from their working locations and

separately packed, together with a bag of

lava-rock. Remove these components and

carefully remove all packing material.

2. Locate burners (one only on G350/9) over injectors

at front, and engage rear locating toes through

corresponding holes in rear supporting angle.

3. Place hearth-surround into casing with tilting

handles to front and ensure that fat trough is

correctly located.

4. Lay bottomgrates in position (Two on G350/9 and

Four on G350/10), ensuring the locating toes on

underside engage in corresponding holes in hearth

surround.

5. LAVA ROCK - DO NOT tip contents of bag of rock

into grates. The dust, which accumulates naturally

at the bag bottomduring shipm

ent, m

ust be

discarded as it will clog burner ports and affect

unit performance. Set a single layer of lava rock,

spread evenly over grate area (see User

Instructions). Discard any small chips of rock as

these may lodge between grates and block heat

flow.

6. Fit brander bars (Three on G350/9 and Six on

G350/10) with flanges toward rear.

7. Having assembled appliance, place it in it's working

position and level it using the feet adjusters. If it is

to be mounted on the special purpose metal stand.

Refer to instructions supplied with stand.

2.2 CONNECTION TO GAS SUPPLY
The gas supply piping and connection to unit must be

installed in accordance with the various regulations

listed on the cover of this manual.
On Natural Gas appliances, the adjustable governor

supplied MUST be fitted in the supply, being securely

fixed in a position enabling adjustments to be made

during commissioning. On Propane units, a governor

must NOT be fitted.

2.3 CONNECTING TO AN ELECTRICAL SUPPLY
Not applicable to these appliances.

2.4 CONNECTION TO WATER SUPPLY
Not applicable to these appliances.

2.5 PRE-COMMISSIONING CHECK
After connecting to gas supply, fit a pressure gauge to

the test point (see Installation, Section 1.9) and check

entire installation for gas tightness. Purge air from

systemand light burners in accordance with

procedures detailed below. On Natural Gas models,

set pressure by means of the governor.
Lighting The Burners
DO NOT attempt to light burners through the

simulated charcoal with a match or short taper

because of the risk of burns.
To Turn A Burner ON (see Figure 1).
A taper (at least 230mm in length) is required.
The following procedure applies to two-burner model

(G350/10).
For single burner unit (G350/9), the lighting operation

will of course be performed once only.
Pull out fat drawer and apply a lit taper through centre

of opening and light either left or right pilot depending

on which burner requires to be lit. Turn gas tap to

required flame position for selected burner.
Check through viewing window that burner is fully

alight before replacing fat drawer.
Repeat above to light other burner.

OFF Position

IGNITION Position

FULL ON Position

LOW FLAME Position

All manuals and user guides at all-guides.com

Содержание G350/10

Страница 1: ...ng had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Mainten...

Страница 2: ...al supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to customer misuse Lubricatio...

Страница 3: ...he table For multiple installations the requirements for individual appliances should be added together Installation should be made in accordance with local and or national regulations applying at the time A competent installer MUST be employed 1 4 GAS SUPPLY The incoming service must be of sufficient size to supply full heat without excessive pressure drop A gas meter will be installed in the sys...

Страница 4: ...it brander bars Three on G350 9 and Six on G350 10 with flanges toward rear 7 Having assembled appliance place it in it s working position and level it using the feet adjusters If it is to be mounted on the special purpose metal stand Refer to instructions supplied with stand 2 2 CONNECTION TO GAS SUPPLY The gas supply piping and connection to unit must be installed in accordance with the various ...

Страница 5: ... data plate To Convert From PROPANE to NATURAL Gas Change gas valve s Change injectors Install governor and adjust for inlet pressure accordingly Adjust low flame setting Adjust burner aeration Change data plate 3 2 REMOVAL OF CONTROL PANEL To remove control panel pull off control knobs and remove fat collecting drawer Remove fixings in top flange of facia panel then lower panel and withdraw it fo...

Страница 6: ...lean one tap at a time To Remove Undo brass nut at compression fitting on gas supply pipe at rear of gas tap Remove thermocouple connection from FFD section of tap Undo fixings and gently remove tap from supply manifold 3 7 GOVERNOR This applies to NATURAL GAS appliances only The type of governor used is maintenance free Check blue dust cap covering vent is fitted and in good condition This protec...

Отзывы: