background image

Burner Adjustment Checks
With burner lit, check flame quality and low flame

setting are in accordance with Section 1.10.
To Turn A Burner OFF
Turn gas tap clockwise to stop, as shown in Figure 1.
Important
After installation, the engineer responsible should

check that all gas connections are good and tight.

Ensure unit is operating satisfactorily before leaving

the premises.

2.6 INSTRUCTION TO USER
After installing and commissioning appliance, please

hand User Instructions to user or purchaser and

ensure that the person(s) responsible understands

instructions for lighting, cleaning and correct use of

unit. It is important to ensure that location of gas

isolating cock is made known to user and that the

procedure for operation in an emergency be

demonstrated.

SECTION 3 - SERVICING and

CONVERSION

Important
BEFORE ATTEMPTING ANY SERVICING,

ENSURE THAT ISOLATING COCK IS TURNED

OFF AND CANNOT BE INADVERTANTLY TURNED

ON.
AFTER ANY MAINTENANCE TASK, CHECK

APPLIANCE TO ENSURE THAT IT PERFORMS

CORRECTLY AND CARRY OUT ANY NECESSARY

ADJUSTMENTS AS DETAILED IN SECTION 1.
After carrying out any servicing or exchange of gas

carrying components -
ALWAYS CHECK FOR GAS TIGHTNESS!!

3.1 CONVERSION TO OTHER GASES
This unit may be set for operation with Natural Gas

(2H) at supply pressure of 20 mbar or propane (3P) at

37 mbar.
For detailed procedures, refer to appropriate sections

of this document.
On completion, reapply any seals and locking nuts.
To Convert From NATURAL to PROPANE Gas
Change gas valve(s).
Change injectors.
Remove governor.
Adjust low flame setting.
Adjust burner aeration.
Change data plate.

To Convert From PROPANE to NATURAL Gas
Change gas valve(s).
Change injectors.
Install governor and adjust for inlet pressure

accordingly.
Adjust low flame setting.
Adjust burner aeration.
Change data plate.

3.2 REMOVAL OF CONTROL PANEL
To remove control panel, pull off control knobs and

remove fat-collecting drawer.
Remove fixings in top flange of facia panel,

then lower panel and withdraw it forward.

3.3 BURNERS
Burners and injectors should be cleaned periodically

to maintain maximum performance.
3.3.1 Main Burner
The adjustment of burner pressure is described in

Section 1.9. Burners are accessed by removing lava

rock, bottomgrates and hearth surround.
Burners are best cleaned with a wire brush,

ports being freed fromblockage with a metal broach,

any loose material being shaken out via burner

shank. Ensure that burners are dry and free from

any cleaning material before replacing.
3.3.2 Pilot Assembly
To remove proceed as follows:
a) Remove branding bars, lava rock, bottomgrates

and hearth.

b) Release themocouple fixing nut and remove

thermocouple from assembly.

c) Release pilot pipe fixing nut frompilot assembly

taking care not to lose injector removed with nut.

d) Undo fixing which secures pilot assembly.
e) Re-assemble in reverse order.

3.4 INJECTORS
Should main injectors become blocked, remove these

fromchargrill for cleaning. First remove lava rock,

bottomgrates, hearth and burners. Unscrew injectors

using a suitable spanner. Soak in solvent to remove

blockage.

3.5 FLAME FAILURE THERMOCOUPLE
To gain access, remove front panel and hearth

surround.
To remove thermocouple from pilot assembly, undo

fixing nut fromwithin control com

partm

ent and

withdraw.
To remove thermocouple from gas tap, undo fixing

nut on tap body.

All manuals and user guides at all-guides.com

Содержание G350/10

Страница 1: ...ng had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Mainten...

Страница 2: ...al supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to customer misuse Lubricatio...

Страница 3: ...he table For multiple installations the requirements for individual appliances should be added together Installation should be made in accordance with local and or national regulations applying at the time A competent installer MUST be employed 1 4 GAS SUPPLY The incoming service must be of sufficient size to supply full heat without excessive pressure drop A gas meter will be installed in the sys...

Страница 4: ...it brander bars Three on G350 9 and Six on G350 10 with flanges toward rear 7 Having assembled appliance place it in it s working position and level it using the feet adjusters If it is to be mounted on the special purpose metal stand Refer to instructions supplied with stand 2 2 CONNECTION TO GAS SUPPLY The gas supply piping and connection to unit must be installed in accordance with the various ...

Страница 5: ... data plate To Convert From PROPANE to NATURAL Gas Change gas valve s Change injectors Install governor and adjust for inlet pressure accordingly Adjust low flame setting Adjust burner aeration Change data plate 3 2 REMOVAL OF CONTROL PANEL To remove control panel pull off control knobs and remove fat collecting drawer Remove fixings in top flange of facia panel then lower panel and withdraw it fo...

Страница 6: ...lean one tap at a time To Remove Undo brass nut at compression fitting on gas supply pipe at rear of gas tap Remove thermocouple connection from FFD section of tap Undo fixings and gently remove tap from supply manifold 3 7 GOVERNOR This applies to NATURAL GAS appliances only The type of governor used is maintenance free Check blue dust cap covering vent is fitted and in good condition This protec...

Отзывы: