SECTION 2 - 
LIGHTING and OPERATION

A 20 second delay 

(approx.)

will occur between

establishing a pilot flame and burner ignition.

The unit will operate automatically with burner going out

when desired temperature is reached. 

Adjustment is available around boiling point.

From pulsing heat to maintain simmer or permanent on

for continuous boil.

Caution

To prevent surge boiling, do not overload baskets and

DO NOT LEAVE UNIT unattended.

Replenishing Water

Replenishment of boiled-off water should take place

during cooking as required. Frequent topping up with

small amounts will avoid significant temperature drops

and shortens recovery time to boiling condition.

Recommended Filling Levels

Always maintain water level between maximum and

minimum level marks on pan rear.

Initial Charging Of The Pan

Prior to first time use, pan should be thoroughly cleaned

using hot water and detergent. Rinse and dry upon

completion.

Ensure drain valve is closed. Fill pan with water up to

level mark. 

Approximate Capacities

G3203

- 17 litres     

G3206

- 28 litres

Lighting The Burner

Warning

After turning off pilot for any reason, wait at least

3 minutes before attempting to relight.

Ensure pan is filled with water prior to lighting. Thermostat

must be turned off

(fully anti-clockwise)

.

A 20 second delay 

(approx.)

will occur between

establishing pilot flame and burner ignition.

The pilot has to be lit using the following procedure:

a) Push control knob in and turn to pilot position.

(See Figure 1)

b) Continue to hold in knob. Press igniter fully in and

release, the spark should light pilot. If pilot does not

light, continue to press and release igniter button until

pilot lights.

c) When lit, hold knob in for 20 seconds then release.

d) Check pilot remains lit. If pilot is extinguished when

knob is released, wait at least 3 minutes before

repeating from Step 1.

SECTION 1 - 
GENERAL DESCRIPTION

The units are provided with wire mesh basket(s) that may

be drained by supporting them upon lift off draining board. 

Water temperature is controlled by an adjustable users

thermostat and a pre-set safety thermostat.

The multifunctional gas control has pilot, main gas and

flame failure controls built in. If pilot flame should

extinguish for any reason or if main gas supply is turned

off burner will shut down until lighting procedure is

repeated.

A spark igniter is fitted to light pilot. A drain valve is

located within controls compartment to empty pan when

necessary.

User Thermostat

This is an adjustable control that provides settings from

70°C through to continuous boil.

Safety Thermostat

This is pre-set at factory. In event of pan boiling dry, safety

thermostat will shut gas off at pilot and main burners.

If this occurs, the reason for failure must be investigated

and rectified. The device is located next to burner control

and is reset by removing black cap that protects button.

Ensure pan has cooled down before filling with cold

water. Push reset button down gently using a slim, blunt

implement 

(i.e. a pen)

and replace cap.

Warning

: Filling an overheated pan with water is

dangerous and may cause damage to pan structure.

Gas Control

Situated at left side of MFC, the control knob is set

correctly when appropriate symbol is alongside position

indicator. 

(See Figure 1)

Flame Failure Device

Operated by pilot flame. If pilot becomes extinguished,

gas will be shut off from main burner.

Warning

If pilot is turned off for any reason, wait a minimum of

three minutes before attempting to relight it. The burner

control is built in to the flame failure device and the

method of operation is detailed here.