Falcon G2102 Скачать руководство пользователя страница 14

3.15  NEONS 

Open oven control panel as detailed in Section 3.2.1. 
Disconnect wiring and push neon out of location. 
Replace in reverse order. 
 

3.16  OVEN LIGHT PUSH BUTTON 

Open oven control panel as detailed in Section 3.2.1. 
Remove push-on connectors at rear.  
Undo rear fixing nut and remove. 
Replace in reverse order. 
 

3.17  OVEN THERMOSTAT 

Open oven control panel as detailed in Section 3.2.1. 
Pull electrical connections off at rear and control knob from front.  
Undo control panel fixings. 
Open oven doors and remove grid shelves. 
Remove RH side panel from oven as detailed in Section 3.2.4 thus revealing thermostat phial.    Remove clips 
securing phial. Also slacken clip which retains capillary tube to inside wall of controls compartment. 
Withdraw thermostat, feeding capillary tube and phial through hole in oven wall. 
Replace in reverse order, taking care to replace insulating sleeving on the capillary tube, and to coil excess tubing out 
of the way of live parts. 

Note 

Re-calibration of thermostat requires use of a special tool, and therefore, cannot be undertaken other than by 
qualified personnel. 
 

3.18  POWER SWITCH 

Open oven control panel as detailed in Section 3.2.1. 
Pull off rear connections. Compress plastic securing tabs, enabling switch to be withdrawn from front. 
To replace, simply push switch into hole, ensuring it is the correct way up. The locating tabs automatically spring into 
position. 
 

3.19  TIMER 

Open oven control panel as detailed in Section 3.2.1. 
Remove push-on connections at rear. Pull off  control knob and undo fixings holding timer to panel. 
Replace in reverse order. 
 

3.20 OVEN FUSE 

Open oven control panel as detailed in Section 3.2.1. 
The fuse is located upon oven control panel side tray. 
Lift off cover to replace fuse. 
To replace fuse holder, RH side panel must be removed as detailed in Section 3.2.5. Remove fuse and undo centre 
fixing. 
 

3.21 OVEN DOOR SEAL 

Seal is fixed to door frame with special spring clips. To remove, simply ease clips from holes. 
Replacement seals are supplied with clips fixed to seal ready for insertion in holes in frame. Seal ends are inserted 
into large holes at door frame corners. After fitting replacement seal, check it closes effectively at all points, 
although minor gaps and cracks can be tolerated without affecting             performance. If necessary, door fit and ball 
catch can be adjusted by removal or addition of shims under hinge brackets and ball catch keeper plate. 
To gain access to brackets and keeper, it is necessary to remove trim immediately above doors and lower grille. 
Adjust shims as necessary to produce necessary fit, endeavouring to achieve        all-round seal contact. 
The ball catch keeper is adjusted by adding or removing shims so the doors are held positively closed with ball 
exerting a slight pressure tending to close them. Also check when oven is hot. 
Shims have slotted holes, therefore it is only necessary to slacken respective fixings in order to remove or replace 
them. 
 
 

Содержание G2102

Страница 1: ... MUST BE EARTHED On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE ...

Страница 2: ... Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to cus...

Страница 3: ...recommended that it be positioned at the RH end to provide unrestricted access for servicing the controls etc Furthermore if installed in a suite either central or adjacent to a wall with a boxed in void at the rear it is vitally important that the void be adequately ventilated to ensure a supply of air to the motor cooling fan at the rear of the oven Important Care must be taken not to disturb th...

Страница 4: ...ested for gas soundness and purged as specified in IGE UP 1 Note The G2102 open top range is supplied complete with the necessary pipework for linking oven and open top burner sections The governor necessary for open top burners is incorporated in this pipework for Natural Gas operation and an extra governor must not be fitted to any of these appliances 1 5 ELECTRICAL SUPPLY The oven is equipped w...

Страница 5: ...ving burner grille below oven doors The rear bolts are accessible via openings in outer back panel Do not raise unit more than is absolutely necessary to effect levelling d Connect to gas supply and test for gas soundness using soap solution or leak detection fluid e Connect to electrical supply ensuring flexible cord does not make contact with flue or other hot areas The wires of flexible cord mu...

Страница 6: ...ven doors Remove control panel and grille base fixings c Lift top unit onto lower unit taking care not to damage upturned flange at rear of lower unit Align back edge of top unit carefully against back flange d Secure top unit to lower unit using M6 x 50mm fixings provided Two at base front corners and two at rear through rectangular openings in lower corners of outer back panel e Fit pipework sup...

Страница 7: ...een removed It is necessary for gas pressure to be checked before the unit is commissioned A suitable pressure gauge must be connected to pressure test point s as follows 2 5 1 Open Top Burners where applicable Pull gas tap knobs off and remove control panel to access test point Refer to Section 1 9 for pressure settings Three burners should be operating on full flame when setting burner operating...

Страница 8: ...veral times 2 5 4 Multifunctional Control Description Access to control is gained upon withdrawal of control panel Refer to Section 3 2 1 This is a two stage multifunctional control which contains a number of features for effecting adjustments Refer to Figure 3 When supplied fitted in unit this component is factory set and should not require adjustment The following adjusters are available a Two t...

Страница 9: ...ce versa 13 Turn 1 STEP ADJ screw anti clockwise no more than a quarter turn If necessary re adjust REG ADJ screw to restore gas pressure to 15mbar 14 Extinguish burner by turning thermostat knob OFF 15 Re light burner by turning thermostat knob to FULL while observing pressure gauge Pressure should initially be 5 mbar pausing for a brief period at this pressure before rising to full pressure of 1...

Страница 10: ...d The location of gas isolating cock and electrical supply switch should be made known to user and the procedure for that operation in an emergency demonstrated SECTION 3 SERVICING and CONVERSION Important BEFORE ATTEMPTING ANY SERVICING ENSURE THAT THE ISOLATING COCK AND MAIN ELECTRICAL SUPPLY ARE TURNED OFF AND THAT IT CANNOT BE INADVERTENTLY TURNED BACK ON Note WHEN REPLACING CONNECTIONS REFER ...

Страница 11: ...s Remove fixings securing fixing bracket to oven wall Remove fixing securing control bracket to valve Replace in reverse order When fitting a replacement control valve transfer gas fittings and fixing bracket from old control to new Set adjustment of replacement valve as detailed in Sections 2 5 4 2 5 5 and 2 5 6 3 3 2 To Remove Open Top Gas Taps G2102 only Remove hob control panel and hob Refer t...

Страница 12: ...order 3 7 REMOVAL and CLEANING of BURNERS 3 7 1 Oven Burner To Remove Withdraw oven control panel as detailed in Section 3 2 1 and remove burner chamber grille Remove pilot burner assembly as detailed in Section 3 6 From inside burner chamber release compression fitting nut on burner feed pipe Remove fixings securing main burner bracket to oven base frame Remove burner complete with mounting brack...

Страница 13: ...es and any loose items Remove oven chamber back panel as detailed in Section 3 2 4 Remove fixings around fan back panel insert Remove nuts from studs around inner periphery and break seal around the edge Using two handles pull fan assembly forward onto base of oven Remove wires from fan motor terminals previously noting location of numbered wires and withdraw assembly clear of the oven Dismantle i...

Страница 14: ...cally spring into position 3 19 TIMER Open oven control panel as detailed in Section 3 2 1 Remove push on connections at rear Pull off control knob and undo fixings holding timer to panel Replace in reverse order 3 20 OVEN FUSE Open oven control panel as detailed in Section 3 2 1 The fuse is located upon oven control panel side tray Lift off cover to replace fuse To replace fuse holder RH side pan...

Страница 15: ...ering any spare parts always quote the appliance type and serial number This information will be found on the data plate attached to the side of the control compartment A short list of spare parts is included in the user manual ...

Страница 16: ...G2112 2102 Wiring Diagram ...

Отзывы: