3.15 NEONS
Open oven control panel as detailed in Section 3.2.1.
Disconnect wiring and push neon out of location.
Replace in reverse order.
3.16 OVEN LIGHT PUSH BUTTON
Open oven control panel as detailed in Section 3.2.1.
Remove push-on connectors at rear.
Undo rear fixing nut and remove.
Replace in reverse order.
3.17 OVEN THERMOSTAT
Open oven control panel as detailed in Section 3.2.1.
Pull electrical connections off at rear and control knob from front.
Undo control panel fixings.
Open oven doors and remove grid shelves.
Remove RH side panel from oven as detailed in Section 3.2.4 thus revealing thermostat phial. Remove clips
securing phial. Also slacken clip which retains capillary tube to inside wall of controls compartment.
Withdraw thermostat, feeding capillary tube and phial through hole in oven wall.
Replace in reverse order, taking care to replace insulating sleeving on the capillary tube, and to coil excess tubing out
of the way of live parts.
Note
Re-calibration of thermostat requires use of a special tool, and therefore, cannot be undertaken other than by
qualified personnel.
3.18 POWER SWITCH
Open oven control panel as detailed in Section 3.2.1.
Pull off rear connections. Compress plastic securing tabs, enabling switch to be withdrawn from front.
To replace, simply push switch into hole, ensuring it is the correct way up. The locating tabs automatically spring into
position.
3.19 TIMER
Open oven control panel as detailed in Section 3.2.1.
Remove push-on connections at rear. Pull off control knob and undo fixings holding timer to panel.
Replace in reverse order.
3.20 OVEN FUSE
Open oven control panel as detailed in Section 3.2.1.
The fuse is located upon oven control panel side tray.
Lift off cover to replace fuse.
To replace fuse holder, RH side panel must be removed as detailed in Section 3.2.5. Remove fuse and undo centre
fixing.
3.21 OVEN DOOR SEAL
Seal is fixed to door frame with special spring clips. To remove, simply ease clips from holes.
Replacement seals are supplied with clips fixed to seal ready for insertion in holes in frame. Seal ends are inserted
into large holes at door frame corners. After fitting replacement seal, check it closes effectively at all points,
although minor gaps and cracks can be tolerated without affecting performance. If necessary, door fit and ball
catch can be adjusted by removal or addition of shims under hinge brackets and ball catch keeper plate.
To gain access to brackets and keeper, it is necessary to remove trim immediately above doors and lower grille.
Adjust shims as necessary to produce necessary fit, endeavouring to achieve all-round seal contact.
The ball catch keeper is adjusted by adding or removing shims so the doors are held positively closed with ball
exerting a slight pressure tending to close them. Also check when oven is hot.
Shims have slotted holes, therefore it is only necessary to slacken respective fixings in order to remove or replace
them.