Check aeration shroud is located in position shown in Figure 3A. There should be no flame lift or light
back. Flames should be blue although slight yellow
tipping is acceptable for propane operation.
Injector should be located centrally within burner venturi
as detailed in Figure 3B.
By-Pass Rates
These are pre-set. To check, proceed as follows:-
Oven Burner
Remove vertical control panel and open lower front panel as detailed in Section 3. Light burner and heat
oven for 45 minutes at a setting of 275ºC before reducing to 125ºC.
Check flame lengths are approximately 5mm long.
Check setting by turning knob to 275ºC and back to 125ºC. The flame should reduce, but not extinguish.
Open and Solid Top Burners
Check flame lengths reduce to approximately 5mm when gas control knob is turned to low flame setting.
The flame should reduce, but not extinguish.