WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
25
A
B
C
ArtNo.311-0010 Injectors
Fig.8-1
A – Jet, B – Internal injector, C – External injector
Grub screw
Grub screw
Fig.8-2
ArtNo.255-0015 - 110DF - Elise removing the control panel
B
B
A
A
A
0
100
140
180
220
0
0
0
0
0
0
0
100
140
180
220
0
Fig.8-3
Check the
‘Technical Data’
section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and the local electricity supply company
requirements. Read the instructions before converting this
appliance.
nn
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
When servicing or replacing gas-carrying
components disconnect from the gas supply before
starting operation. Check the appliance is gas sound
after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electrical supply before
servicing. Before electrical reconnection, check the
appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets
(Fig.8-1)
. Fit the new jets (see the
‘Technical Data’
section at the
back of the book for correct jets). Reassemble in the reverse
order.
Tap Adjustment
Removing the Control Panel
Pull off all the control knobs. Using a 2.5 mm Allen key,
undo the 2 retaining screws in the base at each end of the
handrail and remove
(Fig.8-2)
. Using a 2 mm Allen key, undo
the 2 retaining screws in the base and side of each handrail
support and remove.
Remove the 3 fixing screws (A) from the underside of the
control panel
(Fig.8-3)
. Remove the 2 screws (B) that were
hidden by the handrail supports. Lift the control panel clear,
taking care not to damage or strain the wiring.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig.8-4)
.
Refit the control panel. Locate the holes in the top edge on
the tags on the inner panel and replace the fixing screws in
the bottom edge.
Stick on Label
Stick the LP gas label over the natural gas part of the
appliance data label.
8. Conversion to LP Gas
ArtNo.0102-0011 - Screwing
the control valve bypass screw
Fig.8-4