SECTION 1
– INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER
1.1 MODEL NUMBER, NETT WEIGHTS and DIMENSIONS
MODEL
WIDTH mm
DEPTH mm
HEIGHT mm
WEIGHT kg
E7202
667
570
550
50
1.2 SITING
The units are suitable for installation upon any flat, horizontal surface. Adjustable feet to
facilitate levelling within a limited range. Position oven in desired location and use a suitable
spanner to level.
Sufficent clearance should be left around unit to allow turning for maintenance purposes.
1.3 ELECTRICAL SUPPLY and CONNECTION
These ovens are designed to be connected to a single phase 230V/50hz AC supply.
Check that no damage has occurred to the appliance, power cable and plug top
during transit. If damage has occurred do not use the appliance.
Ensure that the mains power cable is routed free from the appliance to avoid damage.
We recommend supplementary electrical protection with the use of a residual current
device (RCD). Periodic testing, repair and fixed wiring connection should only be
undertaken by a skilled and competent electrician.
The unit power rating is 2.65kW. The mains lead is fitted with a moulded fused plug to
BS1363 with 13 amp fuse fitted. The mains lead wires are coloured in accordance with the
following code:
Green and Yellow EARTH
Blue NEUTRAL
Brown LIVE
These wires should be connected as follows:
EARTH to terminal marked E
NEUTRAL to terminal marked N
LIVE to terminal marked L
Warning - This appliance MUST be earthed!
Any replacement supply cable must be 1.5mm², cord code designation 245 IEC 57 (Cenelec
H05 RN-F). For internal connection, outer sheathing must be stripped 140mm from cable
end. Live and Neutral conductors must be trimmed so that earth conductor is longer by
50mm. Pass inlet cable through rear panel cord grip and ensure cable is routed without
leaving excessive free length inside unit.
The appliance is also provided with a terminal for the connection of an
external equipotential conductor. This terminal is in effective electrical contact
with all fixed exposed metal parts of the appliance, and shall allow the
connection of a conductor having a nominal cross-sectional area of up to 10
mm². It is located on the rear panel and is identified by the following label and
must only be used for bonding purposes.