Table 5 – Gas data
Description
100LT
&
150LT
Lower
calorific
value
H
i
Rated
heating
power
kW
21
Minimum
power
kW
7
Gas
connection
R”
½”
Consumption
G20
–
2H
m
3
/h
2,22
kWh/m
3
9,45
G30/G31
–
3+
Kg/h
1,65
kWh/kg
12,68
Nozzles
diame
ter
in
1/
10
0
mm
G20
20
mbar
Pilot
40
Maximum
3
X
205
Minimum
ADJUST.
G30
G31
28
‐
30/37
mbar
Pilot
20
Maximum
3
X
135
Minimum
ADJUST.
Primary
air
distance
G20
mm
30
G30/G31
Table 6 – Gas inlet pressure
Table
6a
Nominal
main
pressure
for
the
different
types
of
gas
Gas
family
2
–
Natural
20
mbar
Gas
family
3
–LPG
28
‐
30/36
mbar
Table
6b
Operation
permissible
if
pressure
is
in
the
range:
Gas
family
2
–
Natural
da
16
a
25
mbar
Gas
family
3
–LPG
da
20/25
a
35/45
mbar
Table
6c
Operation
non
permissible
if
pressure
is
lower
than:
Gas
family
2
–
Natural
16
mbar
Gas
family
3
–LPG
20/25
mbar
Table
6d
Operation
non
permissible
if
pressure
is
higher
than:
Gas
family
2
–
Natural
25
mbar
Gas
family
3
–LPG
35/45mbar
Содержание 100LT
Страница 20: ...20 4 1 MODEL DIMENSIONS S Overflow A Water connection 3 4 G Gas connection R in conformity with ISO 7 1...
Страница 21: ...21 4 2 MEASURING INLET PRESSURE A Inlet pressure intake B Outlet pressure intake A B...
Страница 23: ...23 4 4 PILOT BURNER A Thermocouple B Pilot burner C Ignition plug D Injector E Tightness screw...
Страница 24: ...24 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A 4 6 PRIMARY AIR REGULATION H...