16
2.6.1 TROUBLESHOOTING
Warning!
Only qualified service personnel can perform the operations described below!
Warning!
Before resetting safety thermostat, it is always necessary to eliminate the problem
causing its activation (only for models with indirect heating)!
Problem and possible cause
Access to components and operation
The content of the pan does not heat:
Safety thermostat has been activated.
Pilot burner is on but main burners do
not light:
loss of pressure in gas supply;
clogged injectors on main burners.
Pilot burner does not light:
clogged injectors on pilot burner;
faulty ignition plug;
check the cable of the ignition plug.
Pilot burner does not remain lit:
faulty
thermocouple;
partially clogged injector on pilot burner;
faulty magnet in control.
Safety thermostat
The safety thermostat can be accessed by removing lower
front panel when the two side screws have been undone.
Main burners
Remove lower front panel.
Pilot burner
Remove lower front panel. Pilot burner is located in front of
combustion chamber.
Ignition plug and thermocouple
Remove lower front panel.
3.1 WARNINGS AND HINTS FOR USER
This manual contains all the instructions required for a proper and safe use of our
appliances.
Keep the manual in a safe place for future consultation!
This appliance is for catering use and must be used only by trained kitchen staff.
The appliance must always be kept under observation during use and never left unattended
Warning!
The manufacturer shall not be held responsible for injuries or damage due to non-
compliance with safety rules or improper use of appliance by the operator.
Some improper operating conditions may even be caused by an improper use of the
appliance, therefore it is important to train personnel properly.
All the installation and maintenance operations must be performed by fitters who are
members of an official register.
Respect the periods required for maintenance. With this is mind, customers are
recommended to sign a service agreement with Serviceline.
In case of failures concerning the appliance, all supplies (gas and water) must be isolated
immediately. In the case of recurrent failure, contact a service technician.
Always turn off products at the end of service.
Never add water to hot oil as an explosion may occur.
Содержание 100LT
Страница 20: ...20 4 1 MODEL DIMENSIONS S Overflow A Water connection 3 4 G Gas connection R in conformity with ISO 7 1...
Страница 21: ...21 4 2 MEASURING INLET PRESSURE A Inlet pressure intake B Outlet pressure intake A B...
Страница 23: ...23 4 4 PILOT BURNER A Thermocouple B Pilot burner C Ignition plug D Injector E Tightness screw...
Страница 24: ...24 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A 4 6 PRIMARY AIR REGULATION H...