background image

24

 

 

4.5 MAIN BURNER 

A. Burner 

 

B. Injector 

C. Injector 

pipe 

 

B

C

A

 

 

 

4.6 PRIMARY AIR REGULATION 

 

 

 

H

Содержание 100LT

Страница 1: ...F900 SERIES User installation and servicing instructions BOILING PAN G9781 Read these instructions before use T100915 REV 5 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Страница 2: ...iance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Dear Cust...

Страница 3: ...e health and safety of all users For further help and information on training and competence we would refer you the Health and Safety Executive website www hse gov uk document ref health and safety tr...

Страница 4: ...Only competent persons are allowed to service or convert the appliance to another gas type Gas appliances must have a stop cock fitted in the supply pipe work The user must be familiar with the locat...

Страница 5: ...ol of the gas inlet pressure 13 2 3 2 Control of primary air flow 13 2 4 Commissioning and testing 14 2 5 Conversion to other types of gas 14 2 5 1 Replacement of injectors for main burners 14 2 5 2 R...

Страница 6: ...1 Size of appliance and position of connections 20 4 2 Measuring the inlet pressure 21 4 3 Gas cock 22 4 4 Pilot burner 23 4 5 Main burner 24 4 6 Primary air regulation 24 4 7 Controls 25 4 8 Relief...

Страница 7: ...urfaces can become hot and require special operation Unplug the appliance in case of failures or improper operation Apply exclusively to a service centre for repairs or maintenance All important infor...

Страница 8: ...ndirect 135 0 5 150LT A Pressure Kettle Indirect 135 0 05 0 5 Table 2 Sizes Refer to Section 4 1 Specifications Models Description Unit of measurement 100LT 150LT Width A mm 800 Depth B mm 900 Height...

Страница 9: ...ADJUST Primary air distance G20 mm 30 G30 G31 Table 6 Gas inlet pressure Table 6a Nominalmainpressureforthedifferenttypesof gas Gas family 2 Natural 20 mbar Gas family 3 LPG 28 30 36 mbar Table 6b Ope...

Страница 10: ...le that cuts off the gas flow if the pilot burner should turn off for any reason The water connection is 3 4 The appliance is equipped with a mixer tap 1 3 1 SPECIAL FEATURES FOR PRESSURE KETTLES Stai...

Страница 11: ...agency electricity board regulations concerning safety the regulations of the electrical power supply company or agency any other local prescriptions 1 5 SPECIAL REQUIREMENTS FOR THE INSTALLATION SIT...

Страница 12: ...ts stated in the technical data plate if the appliance has been designed for these supplies 2 2 1 CONNECTION TO WATER SUPPLY Water inlet pressure must be between 50 and 300 kPa otherwise install a pre...

Страница 13: ...ssure is measured using a liquid pressure gauge e g a U shaped pressure gauge minimum definition 0 1 mbar The supply pressure can be measured directly at the inlet pressure intake on the gas feed pipe...

Страница 14: ...they are expelled without any hindrance The test report must be completed in full and submitted to the customer who should then sign in acceptance With effect from this moment the appliance is covere...

Страница 15: ...connection on the injector tube see figure Measuring gas pressure Set the output pressure of the gas cock according to the figures stated in table 4 Minimum output setting After setting seal the adjus...

Страница 16: ...lug and thermocouple Remove lower front panel 3 1 WARNINGS AND HINTS FOR USER This manual contains all the instructions required for a proper and safe use of our appliances Keep the manual in a safe p...

Страница 17: ...T MOD 100 150LT Warning The jacket water level must be checked each time before lighting Warning It is advised that softened water is used to fill the jacket Open level tap at appliance front Undo fil...

Страница 18: ...by setting knob to maximum heating position When pan reaches cooking temperature turn knob to low position to maintain cooking temperature End of cooking turning off main burner and pilot burner Turn...

Страница 19: ...and isolate all supplies gas and water Apply to a service centre for help The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance with pres...

Страница 20: ...20 4 1 MODEL DIMENSIONS S Overflow A Water connection 3 4 G Gas connection R in conformity with ISO 7 1...

Страница 21: ...21 4 2 MEASURING INLET PRESSURE A Inlet pressure intake B Outlet pressure intake A B...

Страница 22: ...OCK A Thermocouple nut B Gas output C Outlet pressure intake D Inlet pressure intake E Rated output adjustment screw F Gas inlet G Gas connection for pilot burner H Minimum output adjustment screw B C...

Страница 23: ...23 4 4 PILOT BURNER A Thermocouple B Pilot burner C Ignition plug D Injector E Tightness screw...

Страница 24: ...24 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A 4 6 PRIMARY AIR REGULATION H...

Страница 25: ...25 4 7 CONTROLS A Knob C OFF position D Minimum position E Maximum position F Pilot flame position A C F D E 4 8 RELIEF VALVE Pressure Kettle Only Operating position Open position...

Отзывы: