28
SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Technical Data
This cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Behind plinth panel, serial number repeater badge below right hand fan oven opening.
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 915mm
maximum 940mm
Overall width
1000mm See ‘Positioning of Cooker’
Overall depth including handles
660mm
Overall depth excluding handles
600mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
800mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
LP Gas
Hotplate
Injector Bypass
Injector
Bypass
Centre burner
5kW
165
96
5kW (357g/h)
107
57
Large Burners
3kW
120
54
3kW (214g/h)
82
40
Right front burner
1.7kW
95
39
1.7kW (121g/h)
64
32
Gas burner inputs based on Gross Calorifi c Value
Fan Ovens
Forced air convection
2.5kW
Energy effi ciency class
on a scale of A (more effi cient) to G (less effi cient)
C
Energy consumption
based on standard load
1.05kWh
Usable volume
(litres)
49
Size
Medium
Grill
2.5kW
Slow cooking oven
1.2kW
Maximum total electrical load at 230V
8.7kW (approximate total inc. oven fans etc.)
Содержание 1000 DF
Страница 2: ...2...
Страница 3: ...3 English 4 Fran ais 30 FR GB IE...
Страница 56: ...Falcon is a business name of AGA Consumer Products...