Harmonized standards 

 
This  product  complies  with  the  following 
harmonized European standards: 
 
Safety:  EN61010-1 
EMC:    EN61326      
 

 

WEEE and RoHS 

 
Do  not  dispose  of  the  WMA-005/005LF 
amplifier as standard waste, but discard it 
at  a  WEEE  electronic  waste  collection 
point.  The  amplifier  has  been  built  in 
compliance with the RoHS directive. 

 
 

Warranty 

 
Falco  Systems  products  are  guaranteed 
against  malfunction  due  to  defects  in 
materials or workmanship for a period of 1 
year from the date on the invoice. 
If  a  malfunction  occurs  during  this  period, 
the  product  will  be  repaired  or  replaced 
without  charge.  The  product  will  be 
returned  to  the  customer  free  of  charge. 
The warranty does not apply to: 
- Exterior finish or appearance. 
- Malfunction of the product resulting from 
use  or  operation  in  other  ways  than 
specified in the user manual. 
- Malfunctioning due to misuse or abuse of 
the product. 
- Malfunctioning occurring after changes or 
repairs  have  been  made  by  anyone  other 
than Falco Systems. 
 
To  obtain  warranty  service,  inform  Falco 
Systems via 

[email protected]

  

You  will  receive  support  and  further 
instructions. 
 
Falco  Systems  will  not  be  liable  for  any 
consequential damages, including, without 
limitation, devices or equipment connected 
to  the  product,  injury  to  persons  or 
property  or  loss  of  use.  For  more  details 
see  the  Falco  Systems  Standard  Terms 
and Conditions of Sale, which can also be 
downloaded on 

www.falco-systems.com

 

 
 
 
 

 
 
 

User manual version 

 
User manual version: 2.0 
Date: March 26, 2020 
 
 

Falco Systems 

 
Falco Systems BV 
Remisestraat 1   
2225 TH Katwijk aan Zee 
 
Phone:    +31 (0)6 21840996 

 

Email:     

[email protected]

  

Website: 

www.falco-systems.com

 

Содержание WMA-005

Страница 1: ... e g for use in a Faraday cage Its internal high voltage generator is inductor free and hence does not spread magnetic interference in sensitive experimental setups Its large voltage range makes it an excellent choice for use with MEMS devices EO modulators piezo actuator positioning systems beam steering components and many more The amplifiers full power frequency response has a 3dB corner freque...

Страница 2: ...class III product Do not connect the amplifier to the mains safety earth If this is done the system becomes a class I apparatus with class III isolation which means that the protective insulation may be inadequate Doing so only under laboratory conditions is fully at the users risk Risk of electric shock The WMA 005 005LF should not be used above 2000m altitude to prevent electrical breakdown This...

Страница 3: ...e connection can cause overshoot in the oscilloscope reading The amplifier is capable of amplifying above 9kHz and should not be used for telecommunication as described in the R TTE directive 95 5 EC To prevent unwanted radiation all cables should be kept shorter than 30m Noise and offset The WMA 005 is a low noise amplifier The output noise is typically below 3mV rms If this is not low enough the...

Страница 4: ...tage Figure 3 Frequency response at 200mVpp output voltage 140 120 100 80 60 40 20 0 10 0 10 1 10 2 10 3 10 4 10 5 WMA 005 WMA 005LF Amplitude Vpp Frequency Hz 200 150 100 50 0 10 0 10 1 10 2 10 3 10 4 10 5 WMA 005 WMA 005LF Amplitude mVpp Frequency Hz ...

Страница 5: ...5 Figure 4 150Vpp 1kHz square wave Figure 5 Full scale 10kHz square wave Figure 6 30mVpp 1kHz small square wave output signal ...

Страница 6: ...6 0pF 470pF 2 2n 100pF 1nF 10nF Figure 7 Full power 1kHz square wave response with different capacitive loading conditions The 50kΩ output resistor limits the speed at which the capacitor can be charged ...

Страница 7: ...0 Noise less than 10mVpp or equivalently less than 3mVrms and typical DC offset 1 1mV for the WMA 005 The high voltage generator frequency around 150kHz contributes considerable to the overall noise This measurement was performed with 1m of coaxial cable connected to the output ...

Страница 8: ...h typical for the WMA 005 1 1mV offset typical Noise 0 1mVrms noise over the full bandwidth typical for the WMA 005LF 1 5mV offset typical Input impedance 100kΩ Output impedance 50kΩ Stability stable with all capacitive and resistive loads no overshoot 5 Fuse 1x 315mAT 230V Operating temperature 10 40 C Storage temperature 0 60 C Relative humidity 10 90 non condensing Maximum usage height 2000m Di...

Страница 9: ...alfunction of the product resulting from use or operation in other ways than specified in the user manual Malfunctioning due to misuse or abuse of the product Malfunctioning occurring after changes or repairs have been made by anyone other than Falco Systems To obtain warranty service inform Falco Systems via info falco systems com You will receive support and further instructions Falco Systems wi...

Отзывы: