background image

User manual for actuator ZWS12

Contents

1. Safety standards .................................................................................................................................2

2. Description ........................................................................................................................................3

3. Programming the appliance................................................................................................................4

4. Association Groups............................................................................................................................5

5. Compatibility of other producers’ appliances in Z-Wave. ................................................................5

6.  Z-Wave configuration parameters.....................................................................................................5

7.  Alarms and Notifications...................................................................................................................6

8. Technical parameters..........................................................................................................................6

9. Command classes...............................................................................................................................6

10. Manufacturer Specific Report..........................................................................................................7

11. Description of signals – light – emitting diode (LED).....................................................................7

12. Warranty...........................................................................................................................................8

FAKRO Sp. z o.o.

ul. Węgierska 144A

33-300 Nowy Sącz

Polska

www.fakro.com

tel. +48 18 444 0 444

fax. +48 18 444 0 333

02.03.18 NC817-GB                                                                1/8                                                                 ©2018, FAKRO

GB

Содержание ZWS12

Страница 1: ...ces in Z Wave 5 6 Z Wave configuration parameters 5 7 Alarms and Notifications 6 8 Technical parameters 6 9 Command classes 6 10 Manufacturer Specific Report 7 11 Description of signals light emitting diode LED 7 12 Warranty 8 FAKRO Sp z o o ul Węgierska 144A 33 300 Nowy Sącz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 02 03 18 NC817 GB 1 8 2018 FAKRO GB ...

Страница 2: ...tor mentioned on the rated plate Connect the actuator and launch one cycle of work to verify whether it works correctly dual core wire 15V DC Plastic containers used for packing should be kept out of children s reach as they pose a potential threat The actuator should be used only for its purpose FAKRO is not responsible for any damage of the actuator resulting from improper use Any actions relate...

Страница 3: ...ow In order to use the appliance it is essential to install it in accordance with the figure manual attached to its package Programming should be done with any of the remote controls available from Fakro or any remote controls equipped with the Z Wave logo produced by other companies Figure 1 shows a general view of the ZWS12 actuator with a description of the buttons and indicators In the ZWS12 a...

Страница 4: ...function allow you to add actuator to the group of controller Follow the procedur adding device to the selected group according to user manual supplied with the product Then press the programming button P on the actuator for the 1 second Exclude Remove an existed node Exclude This function allow you to remove actuator from the network Z Wave Follow the procedur removing device from the network Z W...

Страница 5: ...ed in this group This group can be a maximum 5 devices 5 Compatibility of other producers appliances in Z Wave Z Wave allows for the integration of other producers appliances for lighting heating domestic automatic appliances etc The Z Wave works in the network as a repeater which enlarges the range of radio communication The more appliances in the network the more resistant to disordered activiti...

Страница 6: ...d Class Version v2 ok Command Class Manufacturer Specific v2 ok Command Class Device Reset Locally v1 ok Command Class Association v2 ok Command Class Association Group Info v1 ok Command Class Powerlevel v1 ok Command Class Switch Binary v1 ok Command Class Switch Multilevel v3 ok ok Command Class Switch All v1 ok Commad Class Configuration v1 ok Command Class Notification v3 ok Command Class Nod...

Страница 7: ...s impossible This diode always appears when the appliance is connecting to a new motor It disappears when the appliance is linked to any network using INCLUDE function Triple blink of the diode The current received from the motor is too intensive A calibration of the actuator motor should be checked A description of outskirts regulation is described in point A of the actuator installation 02 03 18...

Страница 8: ...he appliance was used according to its purpose and in comply with user manual Damage is not an effect of improper power supply installation or an atmospheric conditions The producer is not responsible for any damages arising of improper using and for mechanic damages In case of a damage the appliance should be delivered along with the Warranty Card During the warranty period all damages and defect...

Отзывы: