background image

3. Programming the appliance

.

In order for the appliance to communicate with the  Z-Wave network, it is essential to connect to the network and give  

the appliance a special number (Node ID). The appliance can be added to a network, as long as it does not belong to another one.  In 
order to add the appliance to a network, it should firstly be deleted from any network it belongs to, or restored to factory settings. This  
can be done with the use of any primary controller. The network status diode indicates when the appliance is ready to be linked to the  
network. This diode does not belong to any network. 

In some cases (changing the location of an installation, or changing a damaged appliance), it is necessary to delete the  

appliance from the controllers’ memory, as well as from the network in order to avoid errors and save the batteries of portable  
controllers. 

Do not physically remove the appliance until it has been deleted from the controller’s memory. Improper usage can cause 
delays when trying to use the appliance and will cause the batteries of portable controllers to run out quickly. 

 

Function

Description

Led indication

Motor operating status

Z-Wave operating status

Autoinclusion & Include

(Add a new node)

Autoinclusion

 - This feature allow you to add hard to reach devices to Z-

Wave network. 3-times ON and OFF the power actuator (OFF-ON-OFF-
ON-OFF-ON) causes the introduction of actuator to Autoinclusion mode. 
Please note that the procedure has been started the time between on and off 
can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 
minutes.  During this time, we can add an actuator to any Z-Wave controller 
running in the Include procedure.

-

flashing for up to 10 minutes

Include

 - This function allow you to add actuator to the network Z-Wave. 

Follow the procedur adding device to the network Z-Wave according to user 
manual supplied with the product. Then, press the programming button P on 
the actuator for 1 second.

-

Before: Light ON

After: Light OFF

Association

(Add node to group)

Associate

  – function allow you to add actuator to the group of controller. 

Follow the procedur adding device to the selected group according to user 
manual supplied with the product. Then, press the programming button P on 
the actuator for the 1 second. 

-

-

Exclude (Remove an 

existed node)

Exclude

 - This function allow you to remove actuator from the network Z-

Wave.  Follow   the   procedur   removing   device   from   the   network   Z-Wave 
according   to   user   manual   supplied   with   the   product.  Then,   press   the 
programming   button   P  on   the   actuator   for   1   second.  Function   removes 
information only about newtork Z-Wave.

-

light

Delete

(Remove node from 

group)

Delete

 – function allow you to remove actuator from the group of controller. 

Follow the procedur removing device from the selected group according to 
user manual supplied with the product. Then, press the programming button 
P on the actuator for the 1 second. 

-

-

Factory Default Reset

Device   Reset   Locally

  –  This   function   allows   you   to   reset   the   Z-Wave 

network   without   the   use   of   Z-Wave   controller.   Press   5   times   the 
programming  button  P fast,  the  actuator   was  removed  from the Z-Wave 
network, restore the default parameters, name and locations. Please use this 
procedure only when the network primary controller is missing or otherwise 
inoperable

-

light

Parameter Reset Locally

  – Press fast 3 times P button  on the actuator. 

Function removes information about parameters.

-

Flashing 5 times

Calibration

Manual  

-   Factory   end   positions 

actuator   are   calibrated.   Calibration 
possible   without   necessity   for   prior 
recalibration   of   the   device.   It   is 
performed using buttons available on 
the   control   panel   of   the   ZWS12 
actuator.  Warning!!!  For   the  proper 
calibration of the device requires two 
end positions set correctly.

1. Press P button and manual control 
button   in   the   same   time   on   the 
control panel. 

 Flashing...

-

2.   Press   and   hold   manual   control 
button until reach first end position.

 Flashing...

-

3. Press P button to confirm first end 
position. 

Stop   flashing   and   lit 
cointinously within 2 sec.

-

4. Led  motor   status  blinking   again. 
Press and hold manual control button 
until reach second end position.

Flashing...

-

5. Press P button to confirm second 
end position. 

Stop   blinking   and   lit 
cointinously within 2 sec.

-

02.03.18 NC817-GB                                                               4/8                                                                ©2018, FAKRO

Содержание ZWS12

Страница 1: ...ces in Z Wave 5 6 Z Wave configuration parameters 5 7 Alarms and Notifications 6 8 Technical parameters 6 9 Command classes 6 10 Manufacturer Specific Report 7 11 Description of signals light emitting diode LED 7 12 Warranty 8 FAKRO Sp z o o ul Węgierska 144A 33 300 Nowy Sącz Polska www fakro com tel 48 18 444 0 444 fax 48 18 444 0 333 02 03 18 NC817 GB 1 8 2018 FAKRO GB ...

Страница 2: ...tor mentioned on the rated plate Connect the actuator and launch one cycle of work to verify whether it works correctly dual core wire 15V DC Plastic containers used for packing should be kept out of children s reach as they pose a potential threat The actuator should be used only for its purpose FAKRO is not responsible for any damage of the actuator resulting from improper use Any actions relate...

Страница 3: ...ow In order to use the appliance it is essential to install it in accordance with the figure manual attached to its package Programming should be done with any of the remote controls available from Fakro or any remote controls equipped with the Z Wave logo produced by other companies Figure 1 shows a general view of the ZWS12 actuator with a description of the buttons and indicators In the ZWS12 a...

Страница 4: ...function allow you to add actuator to the group of controller Follow the procedur adding device to the selected group according to user manual supplied with the product Then press the programming button P on the actuator for the 1 second Exclude Remove an existed node Exclude This function allow you to remove actuator from the network Z Wave Follow the procedur removing device from the network Z W...

Страница 5: ...ed in this group This group can be a maximum 5 devices 5 Compatibility of other producers appliances in Z Wave Z Wave allows for the integration of other producers appliances for lighting heating domestic automatic appliances etc The Z Wave works in the network as a repeater which enlarges the range of radio communication The more appliances in the network the more resistant to disordered activiti...

Страница 6: ...d Class Version v2 ok Command Class Manufacturer Specific v2 ok Command Class Device Reset Locally v1 ok Command Class Association v2 ok Command Class Association Group Info v1 ok Command Class Powerlevel v1 ok Command Class Switch Binary v1 ok Command Class Switch Multilevel v3 ok ok Command Class Switch All v1 ok Commad Class Configuration v1 ok Command Class Notification v3 ok Command Class Nod...

Страница 7: ...s impossible This diode always appears when the appliance is connecting to a new motor It disappears when the appliance is linked to any network using INCLUDE function Triple blink of the diode The current received from the motor is too intensive A calibration of the actuator motor should be checked A description of outskirts regulation is described in point A of the actuator installation 02 03 18...

Страница 8: ...he appliance was used according to its purpose and in comply with user manual Damage is not an effect of improper power supply installation or an atmospheric conditions The producer is not responsible for any damages arising of improper using and for mechanic damages In case of a damage the appliance should be delivered along with the Warranty Card During the warranty period all damages and defect...

Отзывы: