Cleaning an Maintenance
Changing motor
protection filter
If the motor protection filter contained in the package
of replacement dust bags is too big, cut it precisely to
the dimension required for your vacuum cleaner. Make
sure that the motor protection filter fits perfectly the
opening of the vacuum motor and does not allow any
dust to get in.
ATTENTION!
The motor protection filter is located behind the dust
bag in the dust chamber.
1. Open the dust bag cover by pulling the release
button
(F)
and remove the dust bag.
2.
Unlock the motor protection filter grid and remove
the motor protection filter, insert a new filter and
close the grid again.
3. Reinsert the dust bag and close the dust bag
cover until it clicks
Notice!
Change cycle, motor protection filter - after the con
-
sumption of approx. 5 dust bags.
The EPA-filter is located under the exhaust air grid on
the rear of the appliance.
1. Release the exhaust air grid by pushing the slide
button side wards in arrow direction.
2.
Remove the old EPA-filter and replace it by a new
one.
3. Reinsert the exhaust air grid until it clicks into
place.
EPA-Filter change
Notice!
Change cycle, EPA-filter after approx. 6 months.