background image

4

When servicing the meter, use only specified 

replacement parts.
Use with caution when working above 30V ac 

rms, 42V peak, or 60V dc. Such voltages pose 

a shock hazard. USE EXTREME CAUTION 

when working with high voltages. 
When using the probes, keep your fingers 

behind the finger guards on the probes.
Connect the common test lead before you 

connect the live test lead. When you disconnect 

test leads, disconnect the live test lead first.
Remove the test leads from the meter before 

you open the case or the cover.
Do not operate the meter with the back cover 

or portions of the case removed or loosened.
To avoid false readings, which could lead to 

possible electric shock or personal injury, 

replace the batteries as soon as the low 

battery indicator (      ) appears.
CAUTION - When an input terminal is connected 

to a dangerous live source it is to be noted that 

a shock potential equivalent to the live source is 

present at all other terminals. USE EXTREME 

CAUTION when working with high voltages.
When measuring a current, turn off the circuit 

power before connecting the meter in the 

circuit. Remember to place the meter in series 

with the circuit.

Содержание FAI DETMULTI

Страница 1: ...FAI DETMULTI Instruction Manual Read this instruction manual thoroughly before use and retain for future reference...

Страница 2: ...ot cover expendable items such as batteries or fuses Warranty Safety Information Electrical Symbols This digital multimeter has been designed according to IEC 1010 concerning electronic measuring inst...

Страница 3: ...leads before you use the meter Do not use the meter if it appears to operate in unusual manner as its safety features may be impaired If in doubt have the meter serviced Do not operate the meter arou...

Страница 4: ...ter before you open the case or the cover Do not operate the meter with the back cover or portions of the case removed or loosened To avoid false readings which could lead to possible electric shock o...

Страница 5: ...o the equipment under test follow these guidelines Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity diodes or capacitance Use the correct termina...

Страница 6: ...gs F250mA 250V Fast Blown 5 x 20 Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents FAI DETMULTI is a handheld 3 digit LCD digital multimeter with the adv...

Страница 7: ...ay auto switch off after approximately 7 seconds 3 Rotary switch Used to turn the meter on and off and select the required function and ranges 4 Hold button When this button is pushed the display will...

Страница 8: ...mperature 0 C 40 C 32 F 104 F Storage temperature 10 C 50 C 14 F 122 F Low battery indication Symbol displayed on the upper left side of the LCD Dimensions 138 x 69 x 31mm Weight approx 170g including...

Страница 9: ...specifications take the form of of Reading Number of Least Significant Digits ACCURACY 0 8 5 1 0 5 RANGE 200mV 2V 20V 200V 600V RESOLUTION 100 V 1mV 10mV 100mV 1V ACCURACY 1 2 10 RANGE 200V 600V RESO...

Страница 10: ...GE DESCRIPTION The approx forward voltage drop of the diode will be displayed on the LCD If the resistance under measurement is less than about 50 the built in buzzer will sound ACCURACY 1 0 5 1 2 5 2...

Страница 11: ...ange by range until satisfactory resolution is obtained 3 Connect the test leads to the source or circuit to be measured 4 Read the voltage value displayed on the LCD along with the polarity of the Re...

Страница 12: ...it 4 Read the current value displayed on the LCD along with the polarity of the Red test lead AC Voltage Measurement 1 Connect the Red test lead to the V mA jack and the Black test lead to the COM jac...

Страница 13: ...eter may take a few seconds to stabilize This is normal for high resistance readings Diode Test 1 Connect the Red test lead to the V mA jack and the Black test lead to the COM jack The polarity of the...

Страница 14: ...he test leads to the two terminals of the circuit to be tested If the resistance is less than about 50 the built in buzzer will sound Test Signal Output 1 Set the Function Range switch to the range 2...

Страница 15: ...the same type 9V battery 6F22 or equivalent then close the case Depleted batteries should be disposed of at your local recycling facility The fuse rarely needs to be replaced and is blown generally a...

Страница 16: ...se the meter for any other special application DISPOSAL OF THIS PRODUCT Dear Customer If you at some point intend to dispose of this article then please keep in mind that many of its components consis...

Отзывы: