13
Resistance Measurement
1. Connect the Red test lead to the "V Ω mA" jack
and the Black test lead to the "COM" jack.
2. Set the Function/Range switch to the desired Ω
range.
3. Connect the test leads to the resistor to be
measured and read the value displayed on the
LCD.
Note
While measuring resistance about 1MΩ and above,
the meter may take a few seconds to stabilize.
This is normal for high resistance readings.
Diode Test
1. Connect the Red test lead to the "V Ω mA" jack
and the Black test lead to the "COM" jack.
(The polarity of the red test lead is positive "+".)
2. Set the rotary switch to "
" range.
3. Connect the Red test lead to the anode of the
diode to be tested and the Black test lead to the
cathode of the diode. The approximate forward
voltage drop of the diode will be displayed on
the LCD. If the connection is reversed, only
figure "1" will be shown.