Installation and user manual
11
3. TECHNICAL SPECIFICATION
Model
IPHC150T
IPHC300T
Advised pool volume (m
3
)
130~260
260~520
Operating air temperature (
℃
)
-10~43
Performance Condition: Air 28°C, Water 26°C, Humidity 80%
Heating capacity (kW)
63,6
116,6
COP at 50% capacity
10,7
10,6
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
40,0
81,0
COP at 50% capacity
6,8
6,8
Sound pressure at 1m dB(A)
54.0~62.0
56.0~65.0
Sound pressure of 50% capacity at 1m
dB(A)
56,0
58,0
Sound pressure at 10m dB(A)
34.0~42.0
36.0~45.0
Compressor
DC-inverter
Heat exchanger
Spiral titanium tube in PVC
Casing
Aluminum-alloy
Fan direction
Vertical
Power supply
400V/3 Ph/50Hz
Rated input power at
air 15°C (kW)
2.20~8.03
4.69~17.6
Rated input current at air 15°C (A)
3.17~11.59
6.77~25.4
Advised water flux (m³/h)
20~25
40~50
Water pipe in-out size (mm)
75
110
Net dimension LxWxH (mm)
1000x1110x1260
2100×1090×128
0
Net weight (kg)
212
459
Gas
(
g
)
5500
11000
GWP
2088
CO2 equivalent (tonnes)
11,48
22,97
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system running at
least 15 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without further notice. For details
please refer to nameplate.