![Fairford XFE Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/fairford/xfe-series/xfe-series_basic-manual-to-the-installation-and-operation_3346109012.webp)
Class10B
AC53a
3.5-12:75-5
Class10
AC53a
3-23:75-5
Class20
AC53a
4-19:75-5
Class30
AC53a
4-29:75-5
Class10B
AC53b
3.5-12:708
Class10
AC53b
3-23:697
Class20
AC53b
4-19:701
Class30
AC53b
4-29:691
3A
3A
3A
3A
5A
4A
3A
3A
6A
6A
6A
6A
9A
9A
7A
6A
8A
8A
8A
7A
12A
12A
9A
8A
13A
13A
10A
9A
18A
19A
12A
11A
19A
19A
18A
17A
23A
28A
21A
20A
23A
23A
22A
21A
31A
34A
26A
24A
27A
27A
25A
24A
35A
40A
30A
29A
33A
33A
31A
30A
45A
49A
37A
35A
35A
35A
30A
28A
46A
43A
33A
31A
41A
44A
35A
33A
47A
51A
39A
37A
44A
46A
44A
43A
56A
72A
55A
51A
55A
55A
55A
54A
85A
89A
69A
64A
70A
70A
59A
58A
85A
84A
63A
61A
77A
85A
66A
64A
86A
92A
70A
67A
88A
98A
75A
73A
94A
105A
80A
77A
98A
108A
83A
81A
107A
117A
89A
85A
116A
128A
99A
96A
126A
139A
106A
101A
132A
135A
112A
106A
146A
159A
122A
115A
154A
166A
131A
124A
171A
186A
143A
134A
179A
190A
151A
142A
203A
215A
167A
156A
Continuous/Optimising
Externally Bypassed
-
1
-
2
-
3
-4
-
5
-
6
-7
-
8
Class10B
AC53a
3.5-12:60-3
Class10
AC53a
3-23:60-3
Class20
AC53a
4-19:60-3
Class30
AC53a
4-29:60-3
Class10B
AC53b
3.5-12:1
188
Class10
AC53b
3-23:1
177
Class20
AC53b
4-19:1
181
Class30
AC53b
4-29:1
171
209A
225A
174A
164A
218A
232A
178A
167A
243A
261A
202A
190A
253A
270A
208A
195A
314A
314A
242A
222A
330A
322A
250A
230A
350A
320A
258A
235A
360A
344A
272A
242A
370A
350A
274A
248A
390A
364A
288A
256A
440A
412A
325A
295A
460A
433A
342A
305A
500A
500A
445A
420A
520A
515A
460A
430A
540A
540A
460A
425A
560A
562A
480A
435A
630A
630A
480A
430A
662A
655A
500A
442A
780A
750A
600A
530A
817A
780A
628A
543A
795A
780A
615A
545A
825A
800A
640A
560A
850A
850A
724A
650A
875A
895A
754A
665A
950A
950A
810A
727A
1000A 1000A
842A
744A
1060A 1060A
904A
812A
1100A
1115A
940A
830A
1150A 1150A
980A
880A
1209A 1210A 1020A
900A
1150A 1150A
980A
880A
1209A 1210A 1020A
900A
1320A 1320A 1050A 930A
1360A 1360A 1080A
950A
1400A 1400A 1110A
950A
1400A 1430A 1160A
970A
1550A 1520A 1230A 1050A 1560A 1580A 1280A 1075A
1850A 1750A 1460A 1190A 1998A 1810A 1520A 1225A
Continuous/Optimising
Externally Bypassed
-
1
-
2
-
3
-4
-
5
-
6
-7
-
8
XFE No.
XFE No.
The owner, installer and user is responsible for the correct installation and use of the XFE and must ensure that
only qualified personnel install the XFE and that the installation, operation and maintenance of the unit complies
with the relevant Codes of Practice, Regulations and Statutory Requirements. The Manufacturer or his agent do
not assume any liability, expressed or implied, for any consequence resulting from inappropriate, negligent or
incorrect installation, application, use or adjustment of the product or circuit design, or from the mismatch of the
unit to a motor. To prevent an electrical shock hazard the XFE must be connected to a safety earth. The unit is not
designed for use in hazardous areas. Use in such an area may invalidate the hazardous area certification.
XFE Current Ratings
Index Ratings
In line with the stated IEC starting duties, all XFE 100 series have an enforced off period of 2 minutes, likewise all
XFE 200 and XFE 300 series have an enforced off period of 7 minutes set as standard. During this period the
display indicates “Stopped.Cooling”, and the XFE will not respond to a start signal.
XFE202
XFE204
XFE206
XFE208
XFE210
XFE212
XFE302
XFE304
XFE306
XFE308
XFE310
XFE312
XFE314
XFE316
XFE318
XFE319
XFE320
XFE322
XFE324
XFE326
XFE102
XFE104
XFE106
XFE108
XFE110
XFE112
XFE114
XFE116
XFE118
XFE120
XFE122
XFE124
XFE126
XFE128
XFE130
XFE132
XFE134
XFE136
XFE138
XFE140