12
N or 0Vdc
110Vac, 230Vac
or 24Vdc
Control Supply
3 phase Supply
Emergency
Stop
Control Supply
M2
M1
Soft Starter
L or 24Vdc
D1-1I
D1COM
N or 24Vdc
K1
K2.1
B1
K3
B2
11
0Vac, 230Vac
or 24Vdc
Control Supply
L or 24Vdc
D
1
-
1
I
D
1
COM
N or 0Vdc
N or 0Vdc
K2.
1
Stop
K0
K
1
.
1
K3.
1
B
1
late
break
K0
T2
K
1
.2
TR.
1
K
1
.4
B
1
K0
TR.2
K3.3
B2
K0
K
1
.3
K3.2
T
1
B
1
33
44
Starter
Start
3 phase Supply
Induction
Motor M1
K
1
B
1
K3
B2
Induction
Motor M2
After emergency
stop button
11
0Vac, 230Vac
or 24Vdc
Control Supply
!
K
1
K3
T
1
K2
TR
B
1
T2
B2
K0
N or 0Vdc
110Vac, 230Vac
or 24Vdc
Control Supply
3 phase Supply
Emergency
Stop
Control Supply
M2
M1
Soft Starter
L or 24Vdc
D1-1I
D1COM
N or 24Vdc
K1
K2.1
B1
K3
B2
11
0Vac, 230Vac
or 24Vdc
Control Supply
L or 24Vdc
D
1
-
1
I
D
1
COM
N or 0Vdc
N or 0Vdc
K2.
1
Stop
K0
K
1
.
1
K3.
1
B
1
late
break
K0
T2
K
1
.2
TR.
1
K
1
.4
B
1
K0
TR.2
K3.3
B2
K0
K
1
.3
K3.2
T
1
B
1
33
44
Starter
Start
3 phase Supply
Induction
Motor M1
K
1
B
1
K3
B2
Induction
Motor M2
After emergency
stop button
11
0Vac, 230Vac
or 24Vdc
Control Supply
!
K
1
K3
T
1
K2
TR
B
1
T2
B2
K0
N or 0Vdc
110Vac, 230Vac
or 24Vdc
Control Supply
3 phase Supply
Emergency
Stop
Control Supply
M2
M1
Soft Starter
L or 24Vdc
D1-1I
D1COM
N or 24Vdc
K1
K2.1
B1
K3
B2
11
0Vac, 230Vac
or 24Vdc
Control Supply
L or 24Vdc
D
1
-
1
I
D
1
COM
N or 0Vdc
N or 0Vdc
K2.
1
Stop
K0
K
1
.
1
K3.
1
B
1
late
break
K0
T2
K
1
.2
TR.
1
K
1
.4
B
1
K0
TR.2
K3.3
B2
K0
K
1
.3
K3.2
T
1
B
1
33
44
Starter
Start
3 phase Supply
Induction
Motor M1
K
1
B
1
K3
B2
Induction
Motor M2
After emergency
stop button
11
0Vac, 230Vac
or 24Vdc
Control Supply
!
K
1
K3
T
1
K2
TR
B
1
T2
B2
K0
Notes
Soft Starter must have stop time set to 0
T1 Time between K1 or K3 closing and the
starter being energised - 0.5 sec minimum.
T2 Time between B1 closing and K3 closing
-Dependant on application - 0.5 sec minimum.
Set to ‘Two wire control’
Emergency stop switch cuts off control
supply and drops out starter and motors.
Stop switch drops control supply from
contactors and timers stopping both motors.
Start switch initiates softstart then
bypass of motor 1 immediately followed
by softstart then bypass of motor 2.
Soft Starter must be rated for
combined starting duty.
The control logic can be continued
for more motors.
The thermal capabilities of synergy
™
should be considered.
Sequential Soft Start diagram
CAUTION
REFER to TABLE 1 on page 8 for input control voltages.
RÉFÉRER au TABLEU 1 à la page 8 pour
des tensions de contrôle d’entrée.