background image

FAIRCHILD MODEL HPD

Pressure Regulator

Installation, Operation and Maintenance Instructions

You can mount the pressure regulator in any 

position without affecting it's operation.

Clean all pipe fittings to remove contaminates 

before installation.

Apply a minimum amount of pipe compound or 

Teflon thread tape to the male threads of the fitting. 

Start with the second thread back and work away 

from the  end of the fitting to avoid thread tape or 

compound from contaminating the pressure 

regulator.

The Inlet and Outlet are labeled "IN" and "OUT". 

Tighten all connections securely. Avoid undersized 

fittings that will limit the flow through the pressure 

regulator

For more information, see Figure 1.

CAUTION

 - Do not rely on the pressure regulator to 

limit the supply pressure from the downstream 

piping system.  Employ properly sized pressure 

limiting device to protect the  piping system 

downstream of the pressure regulator from the 

effects of the supply pressure in the event of a 

pressure regulator failure.

Table 2. Material of Construction

Installation

 

123.9 4.88

 

 

58.4 2.30

 

50.8

2.00  

 

5.5 0.22

 

 

10.2 0.40

 

 

19.1 0.75

 

HPD1***A**K*N

1 Inlet & 1 Outlet Port

1/4 NPTF or BSPT

 

31.8

1.25  

50.5

1.99

34.8

1.37

55.9

2.20

53.8

2.12

 

19.1

0.75  

HPD1*2

N

******

2 x 10-32 UNF-2B X 0.36 dp

HPD1*2

U

******

2 x M5 x 1 X 0.36 dp

Front

 

137 5.40

 

32.8

1.29

3.20.13

 Vent

 

83.8 3.30

 

 

92.7 3.65

 

HPD1***B**T*P

2 Inlet & 2 Outlet Ports

1/4 NPTF or BSPT

Thread

1 3/8 -18

Front

 55° 

 55° 

22.2

0.88  Hex

Dimensions:

[mm]

inches

Figure 1.

 Model HPD Outline Dimensions

2

Valve Body & Bonnet

316 Stainless Steel

Supply & Exhaust Valves 316 Stainless Steel

Seats

CPTFE

PEEK

Vespel SP-1

Diaphragm

Inconel

Seals

PTFE

Springs

Supply Valve

Range Spring

316 Stainless Steel

Music Wire

External Finish

Passivated

Отзывы: