background image

BIO Pellet Stoves

 

29

 

 

 

Work done on:         / 

/   

    

Specialised Technical Servicing Centre  

Work done on:         / 

/   

    

Specialised Technical Servicing Centre  

Work done on:         / 

/   

    

Specialised Technical Servicing Centre  

 

 

 

 

 

 

 

 

 

 

 

 

Material used:  

Guarantee  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

User’s signature  

Segnature of TSC  

 

 

 

 

 

 

 

 

 

 

 

 

 

Material used:  

Guarantee  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

User’s signature  

Segnature of TSC  

 

 

 

 

 

 

 

 

 

 

 

 

 

Material used:  

Guarantee  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

 

 

YES  

 

NO  

User’s signature  

Segnature of TSC  

 

 

Содержание BIO80

Страница 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Страница 2: ...evel Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The control display allows ad...

Страница 3: ...of the installed product Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is...

Страница 4: ...online stove output to room size calculator to help you decide the correct size space for your new stove My Pellet Stove doesn t turn OFF straight away This is because of the built in Cleaning feature...

Страница 5: ...e the stove will extract the smoke given time turning off the stove while there is smoke will cause further smoke to build and not be extracted How to register my new stoves warranty Henley Stoves doe...

Страница 6: ...block chimneys connecting flue pipe system must meet requirements of the Building Regulations We recommend a flexible flue liner system certified for use with solid fuel systems be used to improve sto...

Страница 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Страница 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Страница 9: ...ermetically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid t...

Страница 10: ...minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you can not use pipes made of asbestos cement or flexible metal The pipes must be sealed wi...

Страница 11: ...nly combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets of good quality as that has great influence o...

Страница 12: ...ion methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is...

Страница 13: ...r for 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expecte...

Страница 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Страница 15: ...y B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed Duri...

Страница 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h...

Страница 17: ...ms in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light w...

Страница 18: ...C delta T Menu 05 Menu 06 Menu 07 ATTENTION These menus functions are exclusively for the Technical service improper use can affect the functioning of the stove itself Menu 08 This Menu shall not be...

Страница 19: ...lay A will show the message Off The remote control operates with a 12 Volt MN21 type battery The batteries should be removed from the device before it is disposed of and must themselves be disposed of...

Страница 20: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Страница 21: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Страница 22: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Страница 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inpu...

Страница 24: ...verage temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Страница 25: ...BIO Pellet Stoves 24 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Страница 26: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Страница 27: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Страница 28: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Страница 29: ...rtificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Страница 30: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Страница 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 32: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 33: ...BIO Pellet Stoves 31...

Страница 34: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Отзывы: