BIO Pellet Stoves
17
Menu 04 Stand-by
The stove includes the possibility to enter in the stand-by function. To enable the stand-by function
access the M4 and with the buttons (P1) and (P2) select the value between ON/OFF and confirm with
set (P3). The stove works in this way: if the set temperature of the heater is 20°C with Delta T 01°C,
once it reaches 21°C (then 20°C + 01°C Delta T) and after 10 minutes of time the stove will go off /
standby and resume operation once the temperature drops to 19°C (20°C - 01°C delta T).
Menu 05 / Menu 06 / Menu 07
ATTENTION! These menus (functions) are exclusively for the Technical service, improper use can
affect the functioning of the stove itself.
Menu 08
This Menu shall not be modified as it changes the functioning of the pellet stove activating only the
ambient air ventilator.
If you enter by mistake in this menu, then the pellet stove will not light the flame but will just blow cold
air when ON. You will see on the display one of these messages below.
When this menu is activated you will see on the display the message below when the stove is OFF
To get back to the normal heating functioning of the stove with the flame, just go on Menu 8 again,
select “INVE” and press SET