TROUBLEShOOTING & FAq

EndURancE 50F   

TROUBLEShOOTING & FAq

The 50F Furnace is very trouble free in operation when properly maintained and quality fuel is used. When 

the furnace fails to operate properly, use the following to troubleshoot.

1. No fuel is being dispersed.

Solution:

 Insure the auger tube is primed. If it is, check for jams 

or that the lid is closed (the micro switch on the hopper will 

not let the auger run if open). If not, press manual feed to 

prime the auger.

2. My furnace keeps overloading the burn pot.

 

Solution

: If burning corn check the moisture content of your 

corn. It should be 16% or less. also make sure you are 

using clean corn. Otherwise this is mainly caused by 

improper combustion (See damper adjustment section of 

the Operations Manual). Besides the damper adjustment, 

there are several areas that can have an effect on the 

combustion process. check all gaskets, doors and door 

latching systems for air leaks. any leaks in these areas will 

negatively affect the burn process and cause the pot to 

overload.

3. My furnace isn’t burning and the control is  

displaying LOSS of  FLAME.

 This message indicates the 

Proof of Fire switch no longer senses a flame in the firebox 

area of the furnace. What caused the furnace to go out?

  a. Fuel stopped feeding.

  b. Fire went out due to fuel overloading the fire pot.

  c. The Proof of Fire switch is defective. 

  d. The Proof of Fire switch is defective.

  e. Unit ran out of fuel.

Solution: 

check hopper for fuel.  Press the Prime button to 

ensure fuel is being dispersed. check fire pot to ensure 

proper installation and  re-light the furnace. 

4. My furnace isn’t burning and the controller is  

displaying LOSS of vACUUM. 

This message indicates 

that the Sail switch no longer senses a vacuum in the fur-

nace.

  a. The door of the unit was left open longer than 90 seconds. 

  b. The ash pan door was left open longer than 90 seconds. 

  c. Switch is defective.

  d. Intake air or exhaust path obstructed.

  e. Seals need replacing.

Solution

: Check inner door gasket and ash pan gasket to in

-

sure good seal. check combustion air path for obstruction. 

check to see if combustion blower is still operating by at-

tempting to restart.

5. My furnace isn’t burning and the controller is dis-

playing LOSS of  POWER. 

This means the power was 

interrupted at some point and the unit shutdown.

  

Solution

: Restart furnace if power has been restored.

6. I turned the furnace on with the On/Off switch 

and nothing happens. 

Solution

: First check to see if the Furnace is plugged in and the 

receptacle has power to it. check the fuse on the back of 

the control board. Replace with a 10 a fuse.

7. I turned the furnace on with the On/Off switch 

and the board lights up and the fans come on, 

but the pot doesn’t go into self-clean. 

Solution: 

Unit may be waiting for the sail switch therefore check 

for proper seals and that the fire door and ash pan are 

securely closed. actuators will not move unless vacuum is 

detected.

8. Why is my glass dirty?  

normal operation of your Fahrenheit Technologies Inc. Fur-

nace will produce a light build-up on the glass that wipes 

off with a dry paper towel. However extended burning on 

the low setting only will produce a light tan color. These 

types of build-ups on the glass are normal. a heavy black 

build-up on the glass could indicate a problem.

Solution: 

adjust the combustion air setting to the proper set-

ting. If this doesn’t seem to help, make sure the clean out 

cover plates are installed in the furnace. It also could be an 

indication that the furnace is getting plugged and needs a 

good cleaning. Refer to the section in the manual that  

covers the daily, periodic and yearly maintenance of 

the furnace.

     CAUTION

During troubleshooting some components are hot. Allow unit adequate time to cool. Use gloves as needed.

Содержание Endurance 50F

Страница 1: ...redited These installation instructions must be strictly observed Failure to follow instructions may result in property damage bodily injury or even death Please read this entire manual before install...

Страница 2: ...your new furnace Failure to follow instructions may result in property damage bodily injury or even death CAUTION Failure to follow the instructions in the installation manual may result in a house f...

Страница 3: ...ontrol Board Features Mode and Operating Description 16 Control Board Operation 17 Auto Ignition 18 Manual Ignition 19 Error Descriptions 19 Combustion Air Damper Box 20 Adjustments 21 Cleaning Requir...

Страница 4: ...for shipping These bolts can be used for mobile home installation The front door handle will need to be installed with the screws provided See figure 2 For use in the U S and Canada mobile home appro...

Страница 5: ...ntroller also monitors this Once the set amount has been reached the unit will cycle in the cast re light plate The fuel now falls on this plate and is ignited by the lower flame After it is ignited t...

Страница 6: ...um clearance from combustibles and to allow for furnace maintenance Front 24 minimum clearance from combustibles and to allow furnace maintenance Back Side 6 minimum clearance from combustibles and or...

Страница 7: ...be used inside an existing chimney No clearances to combustibles are needed on sin gle wall stainless steel adapters rigid or flex pipe installed within a chimney A clean out tee PL vent or Quick Conn...

Страница 8: ...p a con centration of fumes 3 Vent surfaces can get hot enough to cause burns if touched by children Non combustible shielding or guards may be required Figure 4 4 1 2 m BELOW a door window cavity or...

Страница 9: ...e a listed PL vent wall thimble Chimney connectors should be made with minimum 24 Gauge black or blue steel 4 When venting into a Class A steel chimney use an appro priate PL Vent adapter The 50F furn...

Страница 10: ...ave a minimum temperature rating of 250 F The plenum of the 50F furnace must be constructed of metal This unit is not to be connected to a chimney flue serving another appliance Once installed check t...

Страница 11: ...t must be used for exhaust venting Single wall vent is not allowed Follow PL vents manufacturer s installation di rections and observe all listed clearances to combustibles WARNING Do not install in a...

Страница 12: ...determine a neutral location to mount the thermostat for accurate room temperature measurements NOTE For installations requiring an external thermostat the 50F furnace must be connected to an approved...

Страница 13: ...sorb moisture from damp or wet floors This will also prevent rodents from becoming a problem Do not store fuel within furnace in stallation clearance areas or within the space required for ash removal...

Страница 14: ...iculty adjusting the 50F furnace contact your dealer or technical support 6 To avoid the possibilities of smoke and or spark entering the room always keep fire chamber door and ash pan drawer secured...

Страница 15: ...BLED WHILE SELF CLEANING IS IN PROGRESS B Menu Returns the screen to the Menu C Prime Allows the user to manually feed fuel into the burn pot on start up when needed This is particularly helpful in pr...

Страница 16: ...Clean Complete Light 2 cups pellets with gel and wait 3 minutes See Quick Start Guide ENTER Done CONTROL BOARD OPERATION Stabilizing LEVEL 3 Fuel 10 P Pellet Vacuum Flame Auger Running LEVEL 3 Fuel 1...

Страница 17: ...Settings The LCD Control Panel will display the MENU of default set tings To change a setting use the UP and DOWN arrows to select the menu item then ENTER to select the options etc 5 Press the ON OF...

Страница 18: ...ions etc 5 Press the ON OFF Button to Start Once the settings are correct for your fuel type etc push the ON OFF Button for approx 1 second The LCD screen will display what process is running Current...

Страница 19: ...d shape Verify the incoming combustion air and the exhaust is free of any debris that could interrupt air flow Insure air damper is open and Sail switch is swinging open by looking into the damper ope...

Страница 20: ...ations If you experience problems adjusting the 50F furnace during the break in period contact your dealer Some chimney systems have abnormal characteristics which can take time to adjust For instance...

Страница 21: ...eaning Prolonged burning at a slow burn rate will result in the need for more frequent window cleaning It is recommended to clean the window when the unit is cold however it is possible to clean the d...

Страница 22: ...leaning of the exhaust sys tem is required Under certain conditions chimneys may plug up rapidly Dirty high moisture content fuel and poor installations require more frequent chimney cleanings See the...

Страница 23: ...to actuator slides 4 The exhaust fan should be cleaned may require a new gas ket Call dealer for this service Annual oiling of the motors is not needed See Figure 15 Fall Startup 1 Prior to lighting...

Страница 24: ...allowed time to cool Positioning Parts for Removal 1 Enter maintenance mode from the Main menu Current Setting 2 Select Auto Pot Removal 3 Close all doors and press Enter 4 Wait for pot parts to be po...

Страница 25: ...e 19 10 Remove the Flapper Door Assembly by lifting upward Figure 20 11 Remove the Burn Shell by lifting up and out Figure 21 Installation of Pot Parts Reverse of steps 6 thru 11 above Figure 21 Figur...

Страница 26: ...When removing the screws take care not to drop the screws between the panels of the unit Remove wire con nectors and carefully remove Igniter and Tube Assembly as shown in Figure 23 3 Remove two lowe...

Страница 27: ...oroughly cooled 2 Never use gasoline or gasoline types such as lantern fluid kerosene charcoal lighter fluid or similar liquids to start or improve a fire in this furnace Keep all such liquids well aw...

Страница 28: ...atic Endurance 50F wiring schematic The electrical rating for this furnace is 115 Volt 60Hz 4 AMP The minimum circuit is 15 AMP CAUTION Call your local dealer for diagnostics and replacement of electr...

Страница 29: ...sary in mild weather even though monthly cleaning may be enough in the coldest months Run the furnace on the hottest setting once a day for 30 45 minutes to pre vent excessive build up in the furnace...

Страница 30: ...nd after installation of this add on furnace by a gas fitter that is recognized by the regulatory authority 8 Do not connect to any gas furnace that is not equipped with an air circulating blower or t...

Страница 31: ...left open longer than 90 seconds b The ash pan door was left open longer than 90 seconds c Switch is defective d Intake air or exhaust path obstructed e Seals need replacing Solution Check inner door...

Страница 32: ...ily and Periodic Maintenance section of the manual If the furnace still does not operate correctly call your dealer for assistance 11 My Furnace isn t burning and the controller is displaying AUGER TI...

Страница 33: ...all costs related to shipping the replacement parts or return of the unit to the factory for replacement If the defect was caused by Fahren heit Technologies Inc then Fahrenheit Technologies Inc will...

Страница 34: ...End Assembly 15 CS1 1390 Sail Switch Assembly 16 CS1 1501 Hopper Top 17 CS1 1505 Lid Switch Arm Item Part Number Description 18 CS1 1550 Top Panel Assembly 19 CS1 2000 Exterior Door Assembly 20 CS1 3...

Страница 35: ...n Gasket 53 CS1 9421 Spider Coupler 54 CS1 9444 Auger Motor 55 CS1 9445 Auger Item Part Number Description 56 CS1 9446 Bronze Bushing 57 CS1 9449 3 8 Coupler 58 CS1 9502 Exhaust Blower Gasket 59 CS1 9...

Страница 36: ...Save This Manual For Future Use Tested to UL391 Standards 526 East 64th Street Holland MI 49423 www fahrenheittech com...

Отзывы: