SMART Pressure Transmitter
FT3351 Series User Manual
July.2022
10 |
P a g e
FAHM Co
.
Industrial Automation
Doc. FT3351Rev1401-05
2.3.3
Housing rotation
To improve field access to the wiring or the visibility of the optional LCD meter, the transmitter
housing may be rotated through 360° and fixed in any position (see Figure 7). A stop prevents
the housing from being turned too far
.
In order to proceed with housing rotation, the housing
stop tang-screw has to be unscrewed by approximately 1 rotation (do not pull it out) and, once
the desired position has been reached, retightened.
Figure 7 Housing rotation
2.4
Electrical considerations
Make sure all electrical installation is in accordance with national and local code requirements.
2.4.1
Conduit installation
If all connections are not sealed, excess moisture accumulation can damage the transmitter.
Make sure to mount the transmitter with the electrical housing positioned downward for
drainage. To avoid moisture accumulation in the housing, install wiring with a drip loop, and