35
The graph shows how the radial force permitted on the axis decreases as the
turning speed increases. The illustration on the right shows the radial force applied
onto the axis [ Fr ] and distance to the ball bearings.
When using mechanical transmission elements, the end of the motor shaft may be
subject to radial loads.
fig.2
“Radial force - turning speed” ratio
Fr
X
Car
g
a
/ Load
[
%
]
[ rpm ]
4500
3000
1500
6000
9000
7500
100
80
90
70
60
50
B3/B5
Note that when installing transmission pulleys or gearboxes, any blow to the shaft reduces
its useful life, of beraings, and may damage the encoder. Therefore, do not hit it for any
reason.
•
Make sure that the maximum radial load values at the end of the shaft do not exceed
the permitted values shown in the table 1.
•
Exceeding these radial load values increases the vibration of the shaft and shortens the
life of the ball bearings and couplings.
Содержание SPM
Страница 1: ...version 0303 in SPM AC SPINDLE MOTOR ...
Страница 2: ......
Страница 15: ...1 1 Fagor Automation S Coop SPM motor manual INTRODUCTION ...
Страница 16: ......
Страница 21: ...7 2 Fagor Automation S Coop SPM motor manual ELECTRICAL CHARACTERISTICS ...
Страница 22: ......
Страница 41: ...27 3 Fagor Automation S Coop SPM motor manual MECHANICAL CHARACTERISTICS ...
Страница 42: ......
Страница 63: ...49 4 Fagor Automation S Coop SPM motor manual INSTALLATION ...
Страница 64: ......
Страница 75: ...61 5 Fagor Automation S Coop SPM motor manual MAINTENANCE ...
Страница 76: ......
Страница 79: ...6 65 Fagor Automation S Coop SPM motor manual SELECTION ...
Страница 80: ......
Страница 86: ...Fagor Automation S Coop SPM motor manual 72 ...