5
4.3
DATA PLATE
The data plate in located on one side of the machine. Under no circumstances should the data plate be
removed from the unit. The data plate is essential to identify the particular features of your machine
and is of great benefit to installers, operators and maintenance personnel. It is recommended that, in
the event the data plate is removed, you copy down the essential information in this manual for
reference before installation. Any transformations or changes made on the machines during installation
should be reflected on the data plate.
4.4
POSITIONING
Leveling and adjusting the height of the appliance is done by turning the leveling stands (Fig. 2) to the
desire height. Ensure that the unit is level (front to back, side to side) before making any connections.
4.5
WATER INSTALLATION
Water installation is carried out as shown in figures 3 and 4. The hot water line to the glass washer
must provide between 20
P
±5
P
psi of water pressure. The hot water heater should be set to deliver
≥
140
°
F
(
≥
60
°
C) water temperature to the glass washer for best results. Use ¾” copper tubing inlet line.
CAUTION:
Do not confuse static pressure with flow pressure. Static pressure is the line pressure in a
“no flow” condition (all valves and services are closed). Flow pressure is the pressure in the fill line
when the solenoid valve is opened during the cycle.
Fig. 2
S
=Gate Valve
F
= Filter
H
= Hose
E
= Fill valve
M
= Pressure Gauge
R
= ¾” Copper
Fig. 3