E25
CONTROL-CONTROL
AUX COMMUNICATION
ERROR
At the start of the running of a programme, if any of the kits (tilting, weighing,
water tanks or extra dosing) is active and no communication is detected between
the main control card and the auxiliary card.
o
If “Cancel” is pressed, the programme will be ended. If “OK” is pressed,
the programme will run but without any of the kits in operation.
o
If communication between the cards is lost while the programme is
running, the kits will not function but in this case no error message is
displayed.
E26
MOTOR HOT WIRE /
VARIATOR ERROR
This error occurs when at any time of the execution of a program, the entry
"Thermal Motor" is opened.
Only the option "end" is given, the programme ends, and the door is unlocked
when this button is pressed.
E27
ERROR NTC OUT OF
RANGE
This error occurs when a temperature value is measured that is above the
configured range (currently the maximum valid value is 110 ºC). This means that
the NTC is broken or disconnected. On detecting that the NTC is out of range, "- -"
is displayed instead of the temperature value.
The 2 options "OK" or "Cancel" are displayed. Press "OK" to continue with the
programme as if the temperature had been reached and consequently skip the
heating phase. Press “Cancel” to end the programme, and unlock the door.
E28
ERROR PRESSURE
SENSOR OUT OF RANGE
This error occurs when a voltage value is measured of less than 0.4 V or more
than 3.8 V. This means that the pressure sensor is broken or disconnected.
This error will not display any buttons and it is only possible to abort by switching
off the machine.