49
OPERATION
Limiting the operating time
In order to increase efficiency, the induction
hob is fitted with a operating time limiter for
each of the cooking zones. The maximum
operating time is set according to the last heat
setting selected.
If you do not change the heat setting for a long
time (see table) then the associated cooking
zone is automatically switched off and the
residual heat indicator is activated. However,
you can switch on and operate individual
cooking zones at any time in accordance with
the operating instructions.
Automatic warm-up function
● Touch sensor field (
5
) to activate the se-
lected cooking zone
● Then sliding your finger across the setting
selection sensor field (
2
) set the desired
heat setting in the 1-8 range and then
touch sensor field (
3
) again.
● The display will alternate between the let
-
ter A and the heat setting.
After a certain time of operation at boost-
ed power, the cooking zone switches
back to the heat setting set, which will be
shown on the display.
If a pot is lifted from the cook-
ing zone and replaced before the
warm-up countdown is completed,
the warm-up function will resume
and countdown will continue until
completed.
Cooking heat
setting
The duration of
the automatic
warm-up
(minutes)
-
1
0.8
2
1.2
3
2.3
4
3.5
5
4.4
6
7.2
7
2
8
3.2
Cooking heat
setting
Maximum op-
erating time
(hours)
8
1
8
2
8
3
5
4
5
5
5
6
1.5
7
1.5
8
1.5
9
1.5
P
0.16