EN
48
6.1
Error diagnosis (MOD.B)
ERROR
DESCRIPTION
CONSEQUENCE
1
OPEN DOOR
The ON/OFF LED lights up for 0.5 seconds and then remains unlit for 2 seconds
before lighting up again. This continues as long as the door is open and the
selected cycle is unfinished.
2
TANK FILL
The ON/OFF LED light up twice for 0.5 seconds each time and then remains unlit
for 2 seconds, then lighting up again twice. This continues while the water in the
tank does not reach the correct level in the specified time.
3
TANK DRAINAGE
The ON/OFF LED lights up three times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again three times. This continues
while the drainage pump does not drain the water in the tank to the correct level in
the specified time.
4
BOILER HEATING
The ON/OFF LED lights up four times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again four times. This continues while the
water in the boiler does not reach the correct temperature in the specified time.
5
TANK HEATING
The ON/OFF LED lights up five times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again five times. This continues while the water
in the tank does not reach the correct temperature in the specified time.
6
BOILER FILL
Le voyant ON/OFF s'allume six fois pendant 0,5 secondes à chaque fois et reste
éteint pendant 2 secondes avant de se rallumer six fois, et ainsi de suite tant que
la chaudière n'a pas atteint le niveau correct dans le temps imparti.
6.2
Errors shown in display (MOD. C)
ERROR DESCRIPTION
DETECTION MODE
CONSEQUENCE
E1
Faulty boiler probe.
TC out of range [-5..200]
MESSAGE: “E1-TC” and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
E2
Faulty tank probe.
TT out of range [-5..200]
MESSAGE: “E2-TT” and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
E3
Tank overheating.
TT > 90 °C
MESSAGE: “E3-TANK” and an acoustic
signal for 30 seconds every 3 minutes,
for 15 minutes. Machine completely
disabled.
E4
Boiler overheating.
TC > 105 °C
MESSAGE: “E4-BOILER” and an
acoustic signal for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
E5
Boiler heating faulty.
If TC<70 °C, and CC is on, if
TC does not change by 3 °C or
more within 5 minutes .
MESSAGE: ”E5-BOILER HEATING”.
The machine is not disabled. The error
is displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes.
E6
Tank heating failure.
60 min without reaching
programmed tank temperature.
MESSAGE: “E6-TANK HEATING”. The
machine is not disabled. The error is
displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes.
E7
The boiler does not fill.
The VC is observed to have
been running for 5 minutes or
more and the PC=PC-ALTO
has not been reached.
MESSAGE: “E7-NEEDS WATER”. The
machine is not disabled. The error is
displayed and an acoustic signal is
emitted for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
E8
The tank does not fill.
Since the start-up of the
machine, PT=PT1 has not been
reached in a period of 30 or
more minutes.
MESSAGE: “E8-TANK EMPTY” and an
acoustic signal for 30 seconds every 3
minutes, for 15 minutes. Machine
completely disabled.
E9
Does not drain.
The BD is observed to have
been running for 1 or more
minutes and the level of the tub
does not go down5mm, (PT
does not change).
MESSAGE: “E9-DOES NOT DRAIN”
and an acoustic signal for 30 seconds
every 3 minutes, for 15 minutes.
Machine completely disabled.