EN
19
remove the nozzles and replace then according
–
to Table 1,
put hob burners’ lids and rings back into place,
–
adjust the hop burner taps and the oven burner
–
taps,
check the connections for soundness.
–
7.4 Adjusting the hob burner taps
The adjustment of hob burner taps is accomplished
by setting the flame on the burner in the simmering
position.
Adjusting the taps:
open the gas flow with the knob and light the bur
-
–
ner to be adjusted,
set the knob in simmering flame position , and
–
then, maintaining that position, remove the knob
from the tap pin and watch the burner’s flame,
turn the adjustment screw “
–
A
” (fig. 7.4.1) and
watch the flame; set the flame to such a size that
will prevent it from being extinguished by a slight
draught or during the operation of quickly turning
the knob from the full to the simmering position of
the flame and back,
the adjustment is correct when the core of the fla
-
–
me is cone-shaped in green and blue colour and
is ca. 2 – 4 mm tall,
if there are perceptible changes of gas pressure
–
in the gas supply system (change in the size of
flame at full flow), the simmering flame should be
set when pressure in the system is low to prevent
the burner from extinguishing during normal use,
upon adjusting the taps, put the knob back in its
–
position and turn off the flame.
The amount of gas used with taps set to minimal gas
flow corresponds to ca. 25 % of use when the taps
are set to full flame.
Table 1 Burner nozzle specification
7.5 Adjusting the oven burner taps
The adjustment of oven burner taps is accomplished
by setting the flame on the oven in accordance with
Table 2.
Adjusting the taps:
take out the accessories from the oven,
–
place the thermocouple in the oven,
–
light the oven burner,
–
set the oven control knob in position „
–
1
” (fig. 7.5.1)
and remove the knob from the tap pin,
close the oven door and heat the oven,
–
after heating the oven check the temperature re-
–
ading on the sensor,
if the temperature in the oven for position „
–
1
” does
not correspond to Table 2, then using a long flat
screwdriver turn the adjustment screw „
B
” in the
right direction to increase or decrease gas flow,
wait a few moments for the temperature in the
–
oven to stabilize; watch the temperature sensor,
if necessary, repeat the adjustment procedure,
–
upon adjusting the taps, put the knob back in its
–
position and turn off the flame.
8.1 The cooker is equipped with the power cord with
a plug and must be connected to a mains socket
properly fitted with earth contact (fig. 8.1.1).
8.2 Connecting the cooker to a socket not equip-
ped with a grounding prong can result in electric
shock should the cooker electrical installation be
damaged.
WARNING!
1. The mains socket should be easily accessible
to the user.
2E-G20 20mbar
3B/P-G30 30mbar
Small
burner
X072
050
Medium burner
Z097
065
Large burner
Y118
085
Oven burner
P1
P2
Oven
Arrangement of
burner nozzles
Содержание CFF 1064GC