Selection criteria
232
5.
S
E
LECT
ING CRI
T
ERIA
Sele
cti
on of
the
synchro
nou
s motor and its associated
dri
ve
210
DDS
HARDWARE
Ref.1310
Summary of the three pre-selections
•
Maximum speed equal to or greater than calculated value in RPM
motor
•
Stall torque equal to or greater than calculate continuous value M
contin-
uous
•
Motor inertia equal to or greater than inertia
J
LOAD
/ k
•
Peak torque equal to or greater than calculated value M
max
•
Rated torque equal to or greater than calculated RMS value M
rms
Drive selection
Once the motor has been selected, check the electrical characteristics ta-
ble in the
FXM/FKM AC servomotors manual.
There are several drives available for each motor and the peak torque ob-
tained with each one of them will be different.
A drive has to be chosen whose peak current is greater than the one cal-
culated for the application.
Содержание APS-24
Страница 1: ...DRIVE DDS Hardware manual Ref 1310...
Страница 6: ...I 6 DDS HARDWARE Ref 1310...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...16 Ref 1310 DDS HARDWARE...
Страница 30: ...1 DESCRIPTION 30 Description DDS HARDWARE Ref 1310...
Страница 94: ...2 POWER SUPPLIES 94 Power supplies DDS HARDWARE Ref 1310...
Страница 188: ...3 DRIVE MODULES 188 Drive modules DDS HARDWARE Ref 1310...
Страница 204: ...4 AUXILIARY MODULES 204 Auxiliary modules DDS HARDWARE Ref 1310...
Страница 232: ...SELECTING CRITERIA 5 232 Selection criteria DDS HARDWARE Ref 1310...
Страница 266: ...7 CABLES 266 Cables DDS HARDWARE Ref 1310...
Страница 312: ...8 INSTALLATION 312 Installation DDS HARDWARE Ref 1310...
Страница 326: ...9 FUNCTIONAL SAFETY 326 Functional safety DDS HARDWARE Ref 1310...
Страница 354: ...10 CONNECTION DIAGRAMS 354 Connection diagrams DDS HARDWARE Ref 1310...
Страница 378: ...12 SALES REFERENCES 378 Sales references DDS HARDWARE Ref 1310...
Страница 384: ...13 COMPATIBILITY 384 Compatibility DDS HARDWARE Ref 1310...
Страница 385: ......