Warning:
If the pipe pressure is different to the fluid pressure, please contact the gas
company. For natural gas, the appliance must not be started at pressures
above 30 mbar. Close the gas inlet to the appliance.
Warning Service pressures exceeding 60 mbar are not allowed as some of the
oven's components could become unusable.
Ventilation
The appliances must be installed in such a way as to allow adequate ventilation
to prevent the unauthorised concentration in the premises of products emitted
during combustion which may be harmful to health.
We recommend the installation of a smoke and steam extraction hood in
accordance with the
UNE–100165:92
standard. The hood should protrude from
the front of the appliance 200-400 mm.
We recommend the annual maintenance by an authorised technician of
the components relating to the gas installation.
TABLE OF CATEGORIES, GASES AND OPERATING PRESSURES
COUNTRY
CATEGORY
PRESSURE
AT
II
2H3B/P
20*50
AL - BG - DK - EE - FI - HR - LT -
LV - MK - NO - RO - SE
II
2H3B/P
20*30
BE - FR
I
2H,
I
3+
20, 30
CH - CY - CZ - ES - GB - GR - IE -
IT - PT - SI - SK - TR
II
2H3+
20*28-30/37
DE - LU
II
2E3B/P
20*50
PL
II
2E3B/P
20*30
HU - IS - MT - NL
I
3B/P
30
Содержание Advance Plus APG-061
Страница 1: ...1 MANUAL DE INSTALACION MODELOS APG 061 APG 101 APG 201 APG 102 APG 202 12044974...
Страница 18: ...ESPA OL MANUAL DE INSTALACION ADVANCE PLUS 18 INSTRUCCIONES DE DESPALETIZACION...
Страница 36: ...ENGLISH INSTALLATION MANUAL ADVANCE PLUS 36 REMOVAL FROM PALLETS INSTRUCTIONS...
Страница 54: ...DEUTSCH INSTALLATIONSHANDBUCH ADVANCE PLUS 54 PALETTE ANWEISUNGEN ZUM ENTFERNEN...
Страница 72: ...FRAN AIS MANUEL D INSTALLATION ADVANCE PLUS 72 LES INSTRUCTIONS DE DEMONTAGE DE PALETTES...
Страница 90: ...ITALIANO MANUALE DI INSTALLAZIONE ADVANCE PLUS 90 ISTRUZIONI DI RIMOZIONE DI IL PALLET...