![FAG Detector III Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/fag/detector-iii/detector-iii_manual_3173195071.webp)
71
Trendline 3
3.5.2 Add bearing
To add a bearing to the bearing database click on
Add bearing
.
·
Select a
manufacturer
from the list.
·
Enter a name for the bearing in the
Label
field.
·
Detailed comments may be entered in the
Comment
field (optional).
Geometry data or damage frequencies
·
Use the
Geometry
and
Frequencies
options to switch between the input fields
in the right-hand area of the window in order to enter corresponding data. When
inputting the contact angle select either
degrees
or
radians
as the unit. When
specifying the frequencies enter whether these should be in
Hz
or
rpm
.