Installation
Page 3/9
2.4.2
Connections
(2)
24-pin screw terminal for connecting the input signals
(3)
3-pin screw terminal for connecting the power supply
(4)
3-pin screw terminal for connecting the communication
2.4.3
Controls
(5)
2-pin plug connector to activate a terminating impedance for the RS-485 interface.
Normally, the communication on the RS-485 network should be trouble-free with-
out activation of the terminating impedance (jumper not plugged in), because the
data rate is comparatively low.
(6)
2-pin plug connector (one per input) to select the input signal (relay contact or volt-
age input).
For use as a relay contact, the jumper must be plugged in (factory setting).
For use as a voltage input, the jumper must not be plugged in.
(7)
4-way DIL switch, currently without function.
2.4.4
LEDs
(8)
Transmit LED TxD (red)
(9)
Receive LED RxD (red)
(10)
Input LEDs (red) - one per input
(11)
Status LED (yellow)
(12)
12 V LED (green) - power for external relay contacts
(13)
Operating voltage LED (green)
2.5
Connection of the power supply
The power supply (230 VAC) has to be a permanent installation. The wires for the power
supply are to be connected to the screw terminals marked with PE, N and L.
Figure 2: Power supply screw terminal
PE
N
L