SEPARIX-C/-T and SEPARIX-Control CT
Page 18/37
•
Inform the technical service responsible for the light liquid separator.
The yellow or red LED will stop blinking as soon as the cause of the fault or alarm
has been corrected by the technical service.
As the configuration of the warning system may have been customised
for the specific application (e.g. disable acknowledge button) or addi-
tional external alarm transmitters may have been connected, you should
ask the technical service to explain how to acknowledge the faults and
alarms in your particular system arrangement.
4.5
Technical data
Measuring transducer
SEPARIX-Control CT
Explosion protection
II (1) G [EEx ia] IIC/IIB
Certificate
TÜV 05 ATEX 2819
Dimensions (H x W x D)
155 mm x 180 mm x 60 mm
Protection class
IP65
Ambient temperature
0 °C … +40 °C
Power supply
230 V AC ± 10%, 50/60 Hz,
≤
8 VA
Connection data
Relay circuit
AC: U
≤
250 V, I
≤
5 A, P
≤
500 VA, cos
ϕ
≥
0,7
DC: U
≤
250 V, I
≤
250 mA, P
≤
50 W
Connection data
SEPARIX-C sensor circuit:
Voltage:
Current:
Power:
Internal resistance:
Capacitance (externally effective):
Inductance (externally effective):
External capacitance:
External inductance:
U
0
≤
14,3 V
I
0
≤
21,2 mA
P
0
≤
75,7 mW
R
i
≥
673
Ω
C
i
≤
1 nF
L
i
negligibly small
IIC
IIB
C
0
≤
680 nF
4,28 μF
L
0
≤
80 mH
300 mH
Connection data
SEPARIX-T sensor circuit:
Voltage:
Current:
Power:
Internal resistance:
Capacitance (externally effective):
Inductance (externally effective):
External capacitance:
External inductance:
U
0
≤
15,8 V
I
0
≤
154 mA
P
0
≤
600 mW
R
i
≥
157
Ω
C
i
≤
0.3 nF
L
i
negligibly small
IIC
IIB
C
0
≤
230 nF 310 nF
760 nF 1,6 μF
L
0
≤
440 μH 100 μH 5 mH 1 mH