Page 3/37
Design and function
3
Design and function
The design of the TORRIX level sensor is illustrated in the version with screw-in unit (see
following figure).
Inside probe head (1) of the level sensor, concealed by cap (2), are the protected terminal
clamps and configuration buttons. The electrical connection is established by an M16 x 1.5
screwed cable gland (3) or M12 plug-in connection at the top of the probe head and by
earth connector (4) at the bottom of the probe head (see chapters “Installation” and “User
configuration”).
On the probe tube (5) is a screw-in unit (6) (cutting ring fitting or ferrule fitting) for height
adjustment capability or a flange (not shown) for fixed installation. The float (7) is the key
component for continuous gauging of the product filling level or interface and is held on
the probe tube by a guard ring (8).
The TORRIX Bypass version is supplied without a process connection and a float.
Figure 1: TORRIX level sensor