Technical data
The following electrical input values apply to the filling level sensors:
Electrical vari-
able
TORRIX Ex SC…
VISY-Stick …
VISY-Stick … TLS
TORRIX Ex …
TORRIX Ex C…
TORRIX Ex RS485…
TORRIX Ex TAG…
VISY-Stick … RS485
U
i
≤
15 V
13 V
30 V
I
i
≤
60 mA
200 mA
200 mA
P
i
≤
100 mW
625 mW
1 W
C
i
<
10 nF
20 nF
10 nF
L
i
<
100 µH
410 µH
20 µH
Table 2: Electrical input data of the filling level sensors
When used in potentially gas explosive atmospheres, please consult table 3 and table 5 for the maximum
temperatures depending on temperature classes and categories or equipment protection levels.
Typ TORRIX Ex SC… bzw. VISY-Stick …
Temperature class
T
a
T
F
Category 1G or equipment protection level Ga (filling level sensor completely installed in Zone 0)
T4, T3, T2, T1
-20 °C … +60 °C
Category 1/2G or EPL Ga/Gb (sensor head installed in Zone 1, and sensor tube in Zone 0)
T6
-40 °C … +50 °C
-20 °C … +60 °C
T5
-40 °C … +65 °C
T4, T3, T2, T1
-40 °C … +85 °C
Category 2G or EPL Gb (filling level sensor completely installed in Zone 1)
T6
-40 °C … +50 °C
-40 °C … +85 °C
T5
-40 °C … +65 °C
-40 °C … +100 °C
T4
-40 °C … +85 °C
-40 °C … +135 °C
T3
-40 °C … +200 °C
T2
-40 °C … +300 °C
T1
-40 °C … +450 °C
Table 3: Operating temperatures of the filling level sensors in basic version (without interface board)
Содержание HART TORRIX
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 41: ...Blank Page ...
Страница 42: ...Blank Page ...
Страница 43: ...Blank Page ...