FAFCO CoolPV Скачать руководство пользователя страница 9

Fafco

®

 

 9 

Commissioning and Warranty Registration 

System Installed By

_____________________________________ 

Install Date: 

___

/

___

/

___ 

(Company) 

FAFCO Installation Stickers Placed: 

(check boxes) 

Thermal Supply 
Thermal Return 

Thermal Drain Valve 
From Pool 
To Pool 

Thermal Supply Isolation Valve 
Thermal Return Check Valve 

This document is to be filled out by the lead solar installer during Installation and Final Commissioning of the CoolPV

®

 Sys-

tem. Keep this form in a safe location and be sure to send a copy to FAFCO, Inc. within 30 days of system installation date 
or system will not be eligible for installer incentive program credits. 

FAFCO Assigned Warranty Registration Number

_____________________________________ 

Array Plumbing Method 

Pipe Used to Plumb System 

System Location 

_____________________________________ 

(Authorized CoolPV Installer) 

Date: 

___

/

___

/

___ 

Roof Orientation 

(circle all that apply) 

N          NE          E          SE          S          SW          W          NW 

Home Owner

_____________________________________ 

(First and Last Name) 

Phone

________________________ 

(Primary) 

Email

_________________________________ 

(For essential contact and warranty registration purposes) 

Installation Address

___________________________________________________________________ 

(House Number, Street, City, State, Zip Code, Country) 

Sales Rep

______________________________ 

(Dealer sales representative who sold system to customer) 

Certification Labels Present: 

(check boxes)

 

OG-100, ICC-SRCC (top header pipe) 

ANSI/UL1703, TUV Rheinland (top header pipe) 

Grounding and Racking: 

(check boxes)

 

Reverse/Return 

End Supply/Return 

CPVC 
PVC 

2

nd

 Story 

1

st

 Story 

Array Layout: 

(check boxes)

 

Sketched 

A copy of the system layout has been: 

Attached 

Panel stickers removed from face of module and included on the system layout. 

Filter Pressure Readings 

Thermal System  OFF: _____  _____ ON: __  ______    Difference: ____  ____    (  )psi / (  )kPa  

UniRac Pro Series Mid Clamps Used 

All Panels Grounded  

All Racking Grounded  

UniRac Solar Mount Racking System Used 

All Mid Clamps Were Tightened and Torqued  

All End Clamps Were Tightened and Torqued  
All Panel Clamps Were Checked for Secure Fastening  

Содержание CoolPV

Страница 1: ...Made in the U S A FAFCO FOR USE WITH SWIMMING POOLS TO ENHANCE SOLAR ELECTRIC PV PERFORMANCE OWNER S MANUAL S o l a r E n e r g y P e r f e c t e d...

Страница 2: ...General Tips For Optimum Performance Owner s Manual Table of Contents 3 3 3 4 5 6 7 8 8 9 10 Figure 1 CoolPV Panel Components Each CoolPV Panel consists of left to right a PV Module a FAFCO Inc Therma...

Страница 3: ...ng your fossil fuel pool heater but not necessarily replace it during the colder less sunny months a pool cover will enhance 1 2 above 4 Give you years of trouble free service Theory of Operation As P...

Страница 4: ...Power Tolerance 0 5 Wp Number of Cells Type 60 Mono crystalline NMOT 43 3 C 2 All performance data calculated at STC Standard Test Conditions 25 C 1000 W m2 1 5 AM Thermal Specifications3 System Opera...

Страница 5: ...Fafco 5 Figure 2 Components of a Typical CoolPV System 11 1 2 3 8 4 5 6 7 9 10 10...

Страница 6: ...ter It is only needed to give your pool a supplemental heat boost or when weather or special occasions demand higher pool temperatures 6 7 Your Pump and Filter For optimal performance a variable speed...

Страница 7: ...l simultaneously If no bubbles appear check the following 1 Ensure that the pump is running 2 Check the isolation valve to make sure it is open 3 Make sure the diverter valve is in the correct positio...

Страница 8: ...mpletely 7 Close the isolation valve 8 Turn on the pool equipment ensuring that the diverter valve is turned to the thermal off posi tion Let the system run for at least 5 minutes while checking to ma...

Страница 9: ..._____________________________ First and Last Name Phone ________________________ Primary Email _________________________________ For essential contact and warranty registration purposes Installation A...

Страница 10: ...e of water flow allows for rapid pool water turnover and proper regula tion of pool chemistry This keeps your pool clean and clear while making the CoolPV System perform optimally 5 In hotter summer m...

Отзывы: