FAFCO CoolPV Скачать руководство пользователя страница 4

Fafco

®

 

 4 

System Specifications 

System Overview 

295W CoolPV

®

 Panel Specifications (CS6K-295MS, PN: 09883) 

1

    

Panel Area 

17.6 ft

(1.67 m

2

Panel Dimensions (HxWxD) 

65 x 39 x 4.72in (1650 x 992 x 120 mm) 

Weight 

55.3 lbs (25.1 kg) 

Roof load 

3.2 psf (15.6 kg/m

2

Fluid Capacity 

0.75 gal (2.8 L) 

Fluid Connection Type 

FAFCO

®

 Proprietary 

Electrical Connection Type 

T4 series 

1

Electical Specifications are based on Canadian Solar Inc. UL1703/UL2703 Certification Ratings  

Electrical Specifications

2

 

295W 

Rated Electrical Output (P

max

295 Watts 

Open Circuit Voltage (V

oc

39.5 V 

Rated Voltage (V

mpp

32.3 V 

Short Circuit Current (I

sc

9.75 A 

Rated Current (I

mpp

9.14 A 

Temperature Coefficient - P

max

 

-0.39 % / K 

Temperature Coefficient - V

oc

 

-0.29 % / K 

Temperature Coefficient - I

sc

 

0.05 % / K 

Electrical Efficiency 

18.02 % 

System Voltage Max 

1000 VDC 

Power Tolerance 

-0 / +5 W

p

 

Number of Cells/Type 

60 / Mono-crystalline 

NMOT 

43±3 

°

2

All performance data calculated at STC (Standard Test Conditions) 25 

°

C, 1000 W / m

2

, 1.5 AM 

 

 

 

Thermal Specifications

3

 

  

  

System Operating Pressure (<100 

°

F) 

20 psi (140 kPa) 

Factory Test Pressure / Burst Pressure Per Collector 

50 psi / 220 psi  (350/1500 kpa) 

Recommended Flow Rate Per Collector 

1.5 gpm (5.7 lpm) 

Delta T (at y intercept) 

3.3 

°

F (1.8°C) 

Operating Temperature Range (typical) 

60-100 

°

F (15-38°C) 

Stagnation Temperature 

140 

°

F (58°C) 

3

All performance data calculated at STC (Standard Test Conditions) 25 

°

C, 1000 W / m

2

, 1.5 AM, Inlet Water of 20 

°

CoolPV

®

 Panels have been certified to meet the following standards: 



ICC-SRCC

TM

 OG-100 Solar Collector Standard (All Sections) 



ANSI/UL1703 Standard for Flat Plate PV Modules and Panels 

 

Section 25: Bonding Path Resistance Test 

 

Section 31: Fire Tests (Class A) 

 

Section 41: Mechanical Load Tests 

Note: CoolPV

® 

Panels maintain a 50psf Design load rating per UL2703, when used with UniRac

®

 

Solar Mount Racking Systems. 

Содержание CoolPV

Страница 1: ...Made in the U S A FAFCO FOR USE WITH SWIMMING POOLS TO ENHANCE SOLAR ELECTRIC PV PERFORMANCE OWNER S MANUAL S o l a r E n e r g y P e r f e c t e d...

Страница 2: ...General Tips For Optimum Performance Owner s Manual Table of Contents 3 3 3 4 5 6 7 8 8 9 10 Figure 1 CoolPV Panel Components Each CoolPV Panel consists of left to right a PV Module a FAFCO Inc Therma...

Страница 3: ...ng your fossil fuel pool heater but not necessarily replace it during the colder less sunny months a pool cover will enhance 1 2 above 4 Give you years of trouble free service Theory of Operation As P...

Страница 4: ...Power Tolerance 0 5 Wp Number of Cells Type 60 Mono crystalline NMOT 43 3 C 2 All performance data calculated at STC Standard Test Conditions 25 C 1000 W m2 1 5 AM Thermal Specifications3 System Opera...

Страница 5: ...Fafco 5 Figure 2 Components of a Typical CoolPV System 11 1 2 3 8 4 5 6 7 9 10 10...

Страница 6: ...ter It is only needed to give your pool a supplemental heat boost or when weather or special occasions demand higher pool temperatures 6 7 Your Pump and Filter For optimal performance a variable speed...

Страница 7: ...l simultaneously If no bubbles appear check the following 1 Ensure that the pump is running 2 Check the isolation valve to make sure it is open 3 Make sure the diverter valve is in the correct positio...

Страница 8: ...mpletely 7 Close the isolation valve 8 Turn on the pool equipment ensuring that the diverter valve is turned to the thermal off posi tion Let the system run for at least 5 minutes while checking to ma...

Страница 9: ..._____________________________ First and Last Name Phone ________________________ Primary Email _________________________________ For essential contact and warranty registration purposes Installation A...

Страница 10: ...e of water flow allows for rapid pool water turnover and proper regula tion of pool chemistry This keeps your pool clean and clear while making the CoolPV System perform optimally 5 In hotter summer m...

Отзывы: