FAFCO CoolPV Скачать руководство пользователя страница 6

Fafco

®

 

 6 

What Do the Various Components Do? 

1. The CoolPV

®

 System 

When used in pool heating applications CoolPV

®

 provides enhanced performance by: 



Cooling the CoolPV

®

 Panels to enhance electrical output. 



Returning the heated water to the pool, extending your swim season. 

2. Solar Drain Valves 

Spigot style valves ensure draining. Some systems may instead connect a hose to the sys-
tem’s lowest point, which can then be run through the downspout of your gutter for easy 
ground access. 

3. The Isolation Valves 

A manually operated valve (3a) is installed in the supply line and allows you to isolate the 
CoolPV

®

 System from the filtration system. It is primarily used when backwashing the filter 

or at any time it is desirable to isolate the system. A check valve (3b) is installed in the re-
turn line to allow isolation and prevent over-pressurizing your system. 

4. Diverter Valve 

Automatically controlled valve that diverts the pool or spa water to the thermal system. 

5. Your  Heater 

It is only needed to give your pool a supplemental heat boost, or when weather or special 
occasions demand higher pool temperatures. 

6 & 7. Your Pump and Filter 

For optimal performance a variable speed pump is preferred. Please contact your FAFCO 
Inc. dealer for more information. Keeping your skimmer and pump baskets clean enhance 
performance by ensuring the maximum flow of cooling water. When cleaning the filter the 
solar system should be isolated, preventing debris from entering the system. 

8. Check Valve 

When the pump (6) shuts off, the CoolPV

®

 System (1) will drain. A Check Valve prevents the 

water in the panels from flowing backwards through the Filter (7) and backwashing. 

9. Vacuum Relief Valve (VRV) 

Seals the system under pressure while maintaining a vacuum to minimize pumping power 
required. The VRV must be located at the highest point in the system. 

10. End Caps 

These seal the headers on the end Solar Collectors in the System. 

11.  Solar Automation Controller 

The Solar Automation Controller regulates the system automatically. By reading sensors on 
the roof and in the pool water, it determines the optimum times run the thermal portion of 
your CoolPV system. 

Содержание CoolPV

Страница 1: ...Made in the U S A FAFCO FOR USE WITH SWIMMING POOLS TO ENHANCE SOLAR ELECTRIC PV PERFORMANCE OWNER S MANUAL S o l a r E n e r g y P e r f e c t e d...

Страница 2: ...General Tips For Optimum Performance Owner s Manual Table of Contents 3 3 3 4 5 6 7 8 8 9 10 Figure 1 CoolPV Panel Components Each CoolPV Panel consists of left to right a PV Module a FAFCO Inc Therma...

Страница 3: ...ng your fossil fuel pool heater but not necessarily replace it during the colder less sunny months a pool cover will enhance 1 2 above 4 Give you years of trouble free service Theory of Operation As P...

Страница 4: ...Power Tolerance 0 5 Wp Number of Cells Type 60 Mono crystalline NMOT 43 3 C 2 All performance data calculated at STC Standard Test Conditions 25 C 1000 W m2 1 5 AM Thermal Specifications3 System Opera...

Страница 5: ...Fafco 5 Figure 2 Components of a Typical CoolPV System 11 1 2 3 8 4 5 6 7 9 10 10...

Страница 6: ...ter It is only needed to give your pool a supplemental heat boost or when weather or special occasions demand higher pool temperatures 6 7 Your Pump and Filter For optimal performance a variable speed...

Страница 7: ...l simultaneously If no bubbles appear check the following 1 Ensure that the pump is running 2 Check the isolation valve to make sure it is open 3 Make sure the diverter valve is in the correct positio...

Страница 8: ...mpletely 7 Close the isolation valve 8 Turn on the pool equipment ensuring that the diverter valve is turned to the thermal off posi tion Let the system run for at least 5 minutes while checking to ma...

Страница 9: ..._____________________________ First and Last Name Phone ________________________ Primary Email _________________________________ For essential contact and warranty registration purposes Installation A...

Страница 10: ...e of water flow allows for rapid pool water turnover and proper regula tion of pool chemistry This keeps your pool clean and clear while making the CoolPV System perform optimally 5 In hotter summer m...

Отзывы: